Maintenance—Every 2000 Hours
VD76477,0000147
–19–18AUG05–1/2
Drain Cooling System
IMPORTANT: Avoid mixing different brands or types
of coolant. Coolant manufacturers
engineer their coolants to meet certain
specifications and performance
requirements. Mixing different coolant
types can degrade coolant and machine
performance.
Drain and flush cooling system using commercial
products, replace radiator cap, and refill with new coolant.
1. Check coolant hoses for cracks and leaks. Replace if
necessary.
2. Check radiator and oil cooler for dirt, grease, leaks,
and loose or broken mountings. Clean radiator and oil
cooler fins.
CAUTION: Prevent possible injury from hot
spraying water. DO NOT remove radiator filler
cap unless engine is cool. Then turn cap slowly
to the stop.
3. Release air to relieve pressure. Remove filler cap.
Zaxis 200LC, 250—Specification
Cooling System—Approximate
Capacity
23.0 L (6.1 gal) With 7 in. Riser
...................................................
24.0 L (6.3 gal) With 48 in. Riser
25.5 L (6.7 gal) With 72 in. Riser
Zaxis 350—Specification
Cooling System—Approximate
Capacity
35.0 L (9.25 gal) With 7 in. Riser
.................................................
35.5 L (9.4 gal) With 48 in. Riser
36.0 L (9.5 gal) With 72 in. Riser
Continued on next page
3-11-1
081407
PN=145