Maintenance—Every 1000 Hours
TX14740,0001F98
–19–09DEC02–1/1
Change Pump Drive Gearbox Oil
T136451
–UN–18DEC00
Zaxis 200LC, 250
T145134
–UN–31AUG01
Zaxis 350
T145092
–UN–31AUG01
1—Dipstick
2—Filler Plug
3—Drain Plug
1. Remove filler plug (2).
2. Remove drain plug (3). Allow oil to drain into a
container. Dispose of waste oil properly.
3. Apply Liquid TEFLON Pipe Thread Sealant to drain
plug. Install plug.
Specification
Pump Drive Gearbox—Oil
Capacity
1.0 L (1.1 qt)
.................................................................................
4. Add oil. (See Section 3-1.)
5. Remove dipstick (1) and check oil level. Oil level must
be approximately halfway below "H" mark.
6. Install filler plug. Install dipstick.