49
PMML0600 rev.0 - 06/2022
5
SP
ACE HEA
TING AND DHW F
OR Y
UT
AKI M / Y
UT
AKI HYDROSPLIT
DRAIN AND WA
TER PIPING
5.5 Space heating and DHW for YUTAKI M / YUTAKI Hydrosplit
!
DANGER
Do not connect the power supply to the unit prior to filling the space heating circuit (and DHW
circuit if it were the case) with water and checking water pressure and the total absence of
any water leakage.
5.5.1 Additional hydraulic necessary elements for space heating
Nature
Nº
Part name
Piping connections
1
Water inlet (Space heating)
2
Water outlet (Space heating)
Field supplied
3
Shut-off valve (field supplied)
Accessories
4
Water check valve
(ATW-WCV-01 accessory)
Field supplied
5
Shut-off valve