List of Holding Registers
Network Data
Func.
Code
Name
R/W
Description
Reg.
Range
Res.
B133
DC bus AVR
selection
R/W Two option codes:
00
}
Disabled
01
}
Enabled
1176h
0, 1
B134
Threshold voltage of
DC bus AVR setting
R/W Setting of threshold voltage of DC bus
voltage to start DC bus AVR function.
Range is:
200V class
}
330 to 395
400V class
}
660 to 790
1177h 330 to 395,
660 to 790
1 V
B140
Over-current trip
suppression
R/W Two option codes:
00
}
Disable
01
}
Enable
10F7h
0, 1
B150
Carrier mode
R/W Automatically reduces the carrier
frequency as the ambient temperature
increases.
00
}
Disable
01
}
Enable
10F8h
0, 1
B151
Selection of RDY
function
R/W Select Ready function.
00
}
Disable
01
}
Enable
10F9h
0, 1
Note 1:
Assume that the inverter current rating is 10000 (for B013/B213).
B
35
Appe
ndix B
B
−
35
Appendix B