400V Class Inverters
The following
tables specify the braking options for
400V class X200 inverters and the
braking torque for each option. You can
connect a single braking unit to the
inverter, or two braking units for
additional braking torque.
Use one BRD
-
EZ3 braking unit for the
braking torque listed in the following
table.
X200 Inverter 400V Models
Braking Torque with BRD
-
EZ3 Braking Unit
External resistor added
Using built
-
in
resistor only
HRB1 x
(
2
)
HRB2 x
(
2
)
HRB3 x
(
2
)
Model Number
HP
Braking
torque
without
braking unit
A
B
A
B
A
B
A
B
004HFEF/HFU
1/2
50%
150%
150%
007HFEF/HFU
1
50%
150%
150%
015HFEF/HFU
2
50%
100%
100%
022HFEF/HFU
3
20%
60%
60%
030HFEF
4
20%
50%
50%
150%
150%
040HFEF/HFU
5
20%
40%
40%
130%
130%
150%
150%
055HFEF/HFU
7.5
20%
30%
30%
100%
100%
130%
130%
075HFEF/HFU
10
20%
20%
20%
70%
70%
100%
100%
Connect a second braking unit in parallel for additional braking torque listed in the
following table.
X200 Inverter 400V Models
Braking Torque with BRD
-
EZ3 Braking Unit
External resistor added
Using built
-
in
resistor only
HRB1 x
(
2
)
HRB2 x
(
2
)
HRB3 x
(
2
)
Model Number
HP
Braking
torque
without
braking unit
A
B
A
B
A
B
A
B
004HFEF/HFU
1/2
50%
150%
150%
007HFEF/HFU
1
50%
150%
150%
015HFEF/HFU
2
50%
150%
150%
022HFEF/HFU
3
20%
130%
130%
030HFEF
4
20%
100%
100%
040HFEF/HFU
5
20%
70%
70%
055HFEF/HFU
7.5
20%
50%
50%
150%
150%
075HFEF/HFU
10
20%
40%
40%
140%
140%
Inverter
+
Braking
unit
Braking
unit
5
7
5
−
7
Inverter System
Accessories