Item
Specification
Note:
■
All 12 slots must be fully installed with
DIMMs.
■
Each DIMM is replaceable when they fail.
■
The DIMM is not common and cannot be
used with DKC DIMM.
Control method
Read LRU, Write after
Battery backup
Provided
Backup duration
Unrestricted (saving to a nonvolatile
memory)
Data in the cache memory is preserved against power failures. If a power outage occurs,
data in cache memory is written to drives.
When the storage system enters Cache Backup mode, the amber
WARNING
LED goes on to
when the system starts. This warning indicates that the battery charge has dropped
significantly and the remaining battery capacity is not sufficient; the storage system will
continue operating with the Write Cache function disabled.
When the battery is charged, the warning indication disappears, and the storage system
continues the operation in the Write Cache function.
The warning indication disappears within six hours. Even when the warning is shown, normal
operation is assured in Write-Through. Read and write performance is lowered because the
Write Cache function is disabled.
If the storage system is not charged for more than six months, the battery can become
overcharged and sustain unrecoverable damage. To avoid this situation, charge the battery
more than 3 hours every six months.
Insulation performance
Item
Specification
Insulation withstand voltage
AC 1,500 V (100 mA, 1 min)
Insulation resistance
DC 500 V, 10 M Ω or more
VSP N400 and VSP N600 mechanical specifications
Appendix A: Mechanical specifications for VSP N400, N600
VSP N400, N600 Hardware Reference Guide