Battery specifications
Storage system intake
temperature
CBSS
CBSL
Up to 75.2º F (24º C)
5 years
5 years
Up to 86º F (30º C)
5 years
4 years
Up to 93.2º (34º C)
4 years
3 years
Up to 104º (40º C)
3 years
2 years
RAID specifications
D: Data drive, P: Parity drive.
Although the storage system with a configuration of RAID 1, RAID 5, or RAID 6 provides
data reliability enhanced by redundancy, there is a chance that user data could be lost
due to an unexpected host, storage system hardware, or software failure. Therefore,
users are requested to back up all data.
Item
Drive tray
RAID Level
SAS, SAS 7.2k, flash drives mounted
RAID 1
2D+2D, 4D+4D
RAID 5
3D+1P, 4D+1P, 6D+1P, 7D+1P
RAID 6
6D+2P, 12D+2P, 14D+2P
Item
Specification
Maximum number of parity groups
88
Maximum volume size
3 TB (or 4 TB when using the LDEVs of
other storage systems)
Maximum volumes/host groups and iSCSI
targets
2,048
Maximum volumes/parity groups
2,048
VSP G200 mechanical specifications (AC power supply model)
Appendix A: Mechanical specifications for VSP G200
Hitachi Virtual Storage Platform G200 Hardware Reference Guide
74