(3) B parameters
Display
code
Function name
Range of setting
Minimum
unit
Setting during
operation
(allowed or not)
Updating during
operation
(allowed or not)
b066
Maximum-limit level of window
comparators O2
-100. to 100. (lower limit : b067 + b068 / 2)
1(%)
○
○
b067
Minimum-limit level of window
comparators O2
-100. to 100. (lower limit : b066 - b068 / 2)
1(%)
○
○
b068
Hysteresis width of window
comparators O2
0 to 10. (lower limit : b066 - b067 / 2)
1(%)
○
○
b070
Operation level at O
disconnection
0 to 100 or "no" (ignore)
1(%)
×
○
b071
Operation level at OI
disconnection
0 to 100 or "no" (ignore)
1(%)
×
○
b072
Operation level at O2
disconnection
-100 to 100 or "no" (ignore)
1(%)
×
○
b078
Cumulative input power data
clearance
Clearance by setting "01" and pressing the STR key
−
○
○
b079
Cumulative input power display
gain setting
1 to 1000.
−
×
×
b082
Start frequency adjustment
10 to 999
0.01 (Hz)
×
○
b083
Carrier frequency setting
*5
0.1 (kHz)
×
×
b084
Initialization mode (parameters
or trip history)
0 (clearing the trip history), 1 (initializing the data),
2 (clearing the trip history and initializing the data)
−
×
×
b085 Country code for initialization
0 (Japan), 1 (EU), 2 (U.S.A.)
−
×
×
b086
Frequency scaling conversion
factor
1 to 990
0.1
○
○
b087 STOP key enable
0 (enabling), 1 (disabling),
2 (disabling only the function to stop)
−
×
○
b088 Restart mode after FRS
0 (starting with 0 Hz), 1 (starting with matching
frequency), 2 (starting with active matching frequency)
−
×
○
b089
Automatic carrier frequency
reduction
0 (invalid), 1 (valid)
−
×
×
b090 Dynamic braking usage ratio
0 to 1000
0.1 (%)
×
○
b091 Stop mode selection
0 (deceleration until stop), 1 (free-run stop)
−
×
○
b092 Cooling fan control
0 (always operating the fan), 1 (operating the fan only
during inverter operation [including 5 minutes after
power-on and power-off])
−
×
○
b095 Dynamic braking control
0 (disabling), 1 (enabling [disabling while the motor is
topped]), 2 (enabling [enabling also while the motor is
topped])
−
×
○
b096 Dynamic braking activation level
200V class: 330 to 380
400V class: 660 to 760
1 (V)
×
○
b098
Thermistor for thermal protection
control
0 (disabling the thermistor), 1 (enabling the thermistor
with PTC), 2 (enabling the thermistor with NTC)
−
×
○
b099 Thermal protection level setting
0 to 9999
1 (
Ω
)
×
○
b100 Free-setting V/f frequency (1)
0 to "free-setting V/f frequency (2)"
1 (Hz)
×
×
b101 Free-setting V/f voltage (1)
0 to 8000
0.1 (V)
×
×
b102 Free-setting V/f frequency (2)
0 to "free-setting V/f frequency (3)"
1 (Hz)
×
×
b103 Free-setting V/f voltage (2)
0 to 8000
0.1 (V)
×
×
b104 Free-setting V/f frequency (3)
0 to "free-setting V/f frequency (4)"
1 (Hz)
×
×
b105 Free-setting V/f voltage (3)
0 to 8000
0.1 (V)
×
×
b106 Free-setting V/f frequency (4)
0 to "free-setting V/f frequency (5)"
1 (Hz)
×
×
b107 Free-setting V/f voltage (4)
0 to 8000
0.1 (V)
×
×
b108 Free-setting V/f frequency (5)
0 to "free-setting V/f frequency (6)"
1 (Hz)
×
×
b109 Free-setting V/f voltage (5)
0 to 8000
0.1 (V)
×
×
b110 Free-setting V/f frequency (6)
0 to "free-setting V/f frequency (7)"
1 (Hz)
×
×
b111 Free-setting V/f voltage (6)
0 to 8000
0.1 (V)
×
×
b112 Free-setting V/f frequency (7)
0. to "free-setting V/f frequency (8)"
1 (Hz)
×
×
b113 Free-setting V/f voltage (7)
0 to 8000
0.1 (V)
×
×
b120 Brake Control Enable
0 (disabling), 1 (enabling)
−
×
○
b121 Brake Wait Time for Release
0 to 500
0.01 (s)
×
○
b122 Brake Wait Time for Acceleration 0 to 500
0.01 (s)
×
○
b123 Brake Wait Time for Stopping
0 to 500
0.01 (s)
×
○
b124 Brake Wait Time for Confirmation 0 to 500
0.01 (s)
×
○
b125
Brake Release Frequency
Setting
0 to 40000
0.01 (Hz)
×
○
b126 Brake Release Current Setting
*6
0.1 (%)
×
○
b127 Braking frequency
0 to 40000
0.01 (Hz)
×
○
Summary of Contents for SJ700 Series Software
Page 8: ...Contents vii ...
Page 10: ......
Page 16: ...Chapter 1 Introduction 1 6 ...
Page 18: ......
Page 24: ...Chapter 2 Creation and Execution of a User Program 2 6 ...
Page 26: ......
Page 30: ...Chapter 3 Syntax 3 4 ...
Page 32: ......
Page 54: ......
Page 102: ......
Page 110: ...Chapter 6 Interface with the Inverter 6 8 ...
Page 112: ......
Page 115: ...Chapter 8 Appendix 8 1 Inverter Parameters and Available Settings 8 1 ...
Page 116: ......