Chapter 6 Interface with the Inverter
6 - 2
6.2 Switching of Operation
6.2.1 Easy sequence function selection (A017)
To enable the easy sequence function, specify "01" (enabling) for the easy sequence function selection
(A017). When the easy sequence function is enabled, the FW terminal is switched to the PRG terminal,
which is used to run the sequence program downloaded to the inverter. (The FW terminal does not
function as the terminal to input the forward-rotation command while the easy sequence function is
operating.)
Function code
Function name
Setting
Remarks
A017
Easy sequence
function selection
00: Off (disabling)
01: On (enabling)
When A017 = 01, the FW terminal
is switched to the PRG terminal.
6.3 Switching of Input/Output Terminals
6.3.1 Program run signal input terminal (PRG terminal)
Turning on the PRG (FW) terminal runs the sequence program downloaded to the inverter. When the
PRG terminal is off, the inverter does not accept the operation command input via the RV terminal, but
waits until the sequence program runs. If the PRG terminal is turned off while the sequence program is
running, the program stops, and all operation command input terminals are turned off.
6.3.2 General-purpose contact input terminals
You can assign functions "56" (MI1) to "63" (MI8) to terminals 1 to 8 (C001 to C008) to use these
terminals as general-purpose input terminals for the easy sequence function. The table below lists the
inverter terminal functions and program variables corresponding to the terminal functions.
When a general-purpose input function is assigned to an intelligent input terminal, the status of the
terminal is reflected in the corresponding program variables (X (00) to X (07) or Xw). If the easy sequence
function is disabled or a program that does not use variables "X (00)" to "X (07)" and "Xw" runs, intelligent
input terminals 1 to 8 will be ineffective even when functions MI1 to MI8 are assigned to the terminals.
You can also assign functions other than MI1 to MI8 to the intelligent input terminals and operate the
terminals for those functions even while a sequence program is running. If both the easy sequence input
and intelligent input functions have been assigned to an intelligent input terminal, the terminal functions
when either input is effective (i.e., both inputs are ORed).
Function code
Intelligent terminal
function
Program variable
Remarks
56
:
MI1 X(00)
or
Xw
57
:
MI2 X(01)
or
Xw
58
:
MI3 X(02)
or
Xw
59
:
MI4 X(03)
or
Xw
60
:
MI5 X(04)
or
Xw
61
:
MI6 X(05)
or
Xw
62
:
MI7 X(06)
or
Xw
Terminal [1] to [8]
functions (C001 to
C008)
63
:
MI8 X(07)
or
Xw
Each terminal can operate
for easy sequence input and
intelligent input. (Both inputs
are ORed.)
Summary of Contents for SJ700 Series Software
Page 8: ...Contents vii ...
Page 10: ......
Page 16: ...Chapter 1 Introduction 1 6 ...
Page 18: ......
Page 24: ...Chapter 2 Creation and Execution of a User Program 2 6 ...
Page 26: ......
Page 30: ...Chapter 3 Syntax 3 4 ...
Page 32: ......
Page 54: ......
Page 102: ......
Page 110: ...Chapter 6 Interface with the Inverter 6 8 ...
Page 112: ......
Page 115: ...Chapter 8 Appendix 8 1 Inverter Parameters and Available Settings 8 1 ...
Page 116: ......