14
Item
no.
Function
Switch
Operating procedure
1 1
Scene file
- SCENE FILE - ・
Scene file adjustment values can be stored
memory
1
in memory by the following procedure.
2
(1) Press the
MEMORY
switch.
3
(2) The
MEMORY
LED begins flashing.
4
(3) Press the scene file (
1
–
4
or
5-8
5-8
) for storing data in the memory.
MEMORY
(4) The selected scene file LED flashes and
the
MEMORY
LED lights for about 3 seconds.
This completes storing memory.
(*1)
The adjustment data of paint gain and
black can not be stored in memory,
(*2)
To stop memory operation,
while the
MEMORY
LED is flashing,
press again the
MEMORY
switch
.
1 2
Shutter control
-SHUTTER-
・
Press
SEL
to toggle the shutter display
ON/OFF
on/off and select the shutter speed and
SEL
mode.
Insequence,1/100(*1),1/250,1/500,1/1000,
1/2000
seconds, variable, AES,CCFR
CCFR
(*2)
→100
(*1)
→ 250
→ 500
→
1000
↑
AES
(*3)
59
2000
Variable mode
1/59 to 1/1983 (1080i/60)
1/50 to 1/2008 (1080i/50)
(*1) 1/60 ,when 1080i/50 CCD is used.
(*2) CCFR: cc frame mode
(*3) AES:auto electric shutter mode
・
For variable mode, after selecting the
manual control section
SHUTTER
switch,
1 3
Master gain
-MASTER GAIN- ・
Master gain can be selected in 3 dB steps.
selection
<
>
(-3dB~24dB)
・
Selected master gain position is indicated
by the LED on left of this switch.