4 Electrical wiring
137
4
SMGB0077 rev.0 - 01/2013
Test runs
C A U T I O N
•
Be careful during the test runs, as some of the safety functions remain disabled: the units operate for two hours
without switching off via the thermostat. The three-minute compressor protection is not enabled during the test.
•
Secure the rubber bushes to the panel using adhesive when the outdoor unit ducts are not used.
•
The compressor remains at a standstill during forced stoppage.
4.1.5
Electrical connection of RPC units
Work prior to the electrical connection
1
Turn off the power supply switches before starting work and fit the appropriate locks and safety warnings.
2
Wait 5 minutes after turning off the power supply switches.
3
Check that the fans on the indoor and outdoor units are at a standstill before starting work.
N O T E
•
The electrical power for the unit must involve a specific power line, with an exclusive power control switch and
residual current breaker, installed in line with local or national safety regulations.
•
Check that the electrical power line has enough capacity to supply the unit. Its length, the cable diameter and
their protection (sleeve or jacket) must be appropriate for the unit.
•
For further information, always consider the current regulations in the country where the unit is to be installed.
C A U T I O N
•
Risk of fire: cables must never touch the refrigerant pipes, printed circuit boards (PCB), sharp edges or elec
-
trical components inside the unit to avoid damaging them.
•
Loose connection terminals may lead to cable and terminal overheating. The unit may operate incorrectly,
leading to a risk of fire. Check that the cables are firmly secured to the connection terminals.
Electrical connection
Check that the power supply for the RPC indoor unit is 230 V. If not, replace connectors CN on the TF transformers in the
electrical box.
N O T E
•
To prevent the screws from falling from the terminal box, do not remove them completely, hold onto the termi-
nal and check that the screw is secure through the hole in the terminal.
•
Use the following screws for the terminal box:
-
M4 screw for the power supply.
-
M3.5 screw for the operating line.
Follow the steps below to connect the remote control cable or the optional extension wire:
1
Pass the cable through the knockout hole in the cabinet.
2
Connect the cable to terminals A and B of the terminal strip (TB).
3
Tighten the screw on terminals A and B.
4
Check that the cables are correctly secured.
Follow the steps below to connect the power cables to the terminal strip (TB):
1
Where necessary, loosen the screws on terminals L1 and N on the terminal strip (TB).
2
Connect the power cables to terminals L1 and N.
3
Tighten the screws on terminals L1 and N.
4
Check that the cables are correctly secured.
Summary of Contents for RCD-2.5FSN2
Page 2: ......
Page 4: ...SMGB0077 rev 0 01 2013 IV Index ...
Page 12: ...TCGB0077 rev 0 01 2013 XII Index ...
Page 24: ......
Page 102: ...2 Unit installation 90 SMGB0077 rev 0 01 2013 ...
Page 180: ...4 Electrical wiring 168 SMGB0077 rev 0 01 2013 Wiring diagrams for RCIM 0 8 2 0 FSN2 ...
Page 191: ...4 Electrical wiring 179 4 SMGB0077 rev 0 01 2013 DX Interface EXV 2 0 10 0 E1 ...
Page 192: ...4 Electrical wiring 180 SMGB0077 rev 0 01 2013 ...
Page 218: ......
Page 264: ...7 Test run 252 SMGB0077 rev 0 01 2013 ...
Page 276: ...9 Spare parts 264 SMGB0077 rev 0 01 2013 9 1 RCI 1 0 6 0 FSN3 SPN201201 ...
Page 278: ...9 Spare parts 266 SMGB0077 rev 0 01 2013 9 2 RCI 1 0 1 6 FSN3Ei EPN 201204A ...
Page 282: ...9 Spare parts 270 SMGB0077 rev 0 01 2013 9 4 RCD 1 0 3 0 FSN2 ...
Page 284: ...9 Spare parts 272 SMGB0077 rev 0 01 2013 9 5 RCD 4 0 5 0 FSN2 ...
Page 286: ...9 Spare parts 274 SMGB0077 rev 0 01 2013 9 6 RPC 2 0 6 0 FSN2E ...
Page 288: ...9 Spare parts 276 SMGB0077 rev 0 01 2013 9 7 RPI 0 8 1 5 FSN4E ...
Page 290: ...9 Spare parts 278 SMGB0077 rev 0 01 2013 9 8 RPI 2 0 3 0 FSN4E EPN 201208A 1B ...
Page 292: ...9 Spare parts 280 SMGB0077 rev 0 01 2013 9 9 RPI 4 0 6 0 FSN4E EPN 201208A 2B ...
Page 294: ...9 Spare parts 282 SMGB0077 rev 0 01 2013 9 10 RPI 8 0 10 0 FSN3E EPN 201108A 1B ...
Page 296: ...9 Spare parts 284 SMGB0077 rev 0 01 2013 9 11 RPIM 0 8 1 5 FSN4E DU EPN 201206A 2B ...
Page 298: ...9 Spare parts 286 SMGB0077 rev 0 01 2013 9 12 RPK 0 8 1 0 FSN H 3M ...
Page 300: ...9 Spare parts 288 SMGB0077 rev 0 01 2013 9 13 RPK 1 5FSN H 3M ...
Page 302: ...9 Spare parts 290 SMGB0077 rev 0 01 2013 9 14 RPK 2 0 4 0 FSN3M ...
Page 304: ...9 Spare parts 292 SMGB0077 rev 0 01 2013 9 15 RPF 1 0 2 5 FSN2E ...
Page 306: ...9 Spare parts 294 SMGB0077 rev 0 01 2013 9 16 RPFI 1 0 2 5 FSN2E ...
Page 308: ...9 Spare parts 296 SMGB0077 rev 0 01 2013 9 17 KPI 252 2002 E H 3E and KPI 502 1002 X3E ...
Page 310: ...9 Spare parts 298 SMGB0077 rev 0 01 2013 9 18 DX Interface ...