Safety precautions

·

Perform grounding

   Do not connect the earth wire to a gas pipe, water pipe, lightning rod or telephone earth wire. 
   Defective grounding could cause an  electric shock.

·

Do not install the unit in a place where inflammable gas leaks.

    If gas leaks and accumulates in the area surrounding the unit, it could cause an explosion.

·

Fasten a flare nut with a torque wrench as specified in this manual.

    When fastened too tightly, a flare nut may break after a long period, thereby causing refrigerant leakage.

·

Install an earth leakage breaker depending on the installation place(where it is humid). 

    If an earth leakage breaker is not installed, it could cause an electric shock.

·

Perform the drainage/piping work securely according to the installation manual.

·

If there is a defect in the drainage/piping work, water will drop from the unit and household items

    will get wet and damaged.

C

AUTION

2

·

Do not let air enter the refrigeration system or discharge refrigerant when moving the air conditioner.

·

The installation instructions for appliances that are intended to be permanently connected to fixed 

    wiring, and have a leakage current that may exceed 10 mA, shall state that the installation of a 
    residual current device (RCD) having a rated residual operating current not exceeding 30 mA is 
    advisable.

·

This appliance is not intended for use by persons (including children) with reduced physical, sensory 

    or mental capabilities, or lack of experience and knowledge, unless they have been given supervision 
    or instruction concerning use of the appliance by a person responsible for their safety. 
    Children should be supervised to ensure that they do not play with the appliance.  

·

If the appliance is fixed wiring, the appliance must be fitted with means for disconnection from the 

    supply mains having a contact separation in all poles that provide full disconnection under over 
    voltage category III conditions, and these means must be incorporated in the fixed wiring in 
    accordance with the wiring rules.

·

If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly 

    qualified persons in order to avoid a hazard.

·

The appliance shall be installed in accordance with national wiring regulations.

·

Servicing shall only be performed as recommended by the equipment manufacturer.

Safety Instructions

·

The method of connection of the appliance to the electrical supply and interconnection of separate 

    components is detailed in below part. The wiring diagram with a clear indication of the connections
    and wiring to external control devices and supply cord is detailed in below part. The cord of the 
    H07RN-F type or the electrically equivalent type must be used for power connection and 
    interconnection between outdoor unit and indoor unit. The size of the cord is detailed in below part.

·

In order to avoid a hazard due to inadvertent resetting of the thermal cut-out, this appliance must not

    be supplied through an external switching device, such as a timer, or connected to a circuit that is 
    regularly switched on and off by the utility.

·

It is necessary to allow disconnection of the appliance from the supply after installation. The 

    disconnection may be achieved by incorporating a

 

switch in the fixed wiring in accordance with the 

    wiring rules. During service and when replacing parts, be sure to disconnect the appliance from its 
    power source. If the disconnection is not foreseen, and provide a disconnection with a locking system 
    in the isolated position.

·

Details of type and rating of fuses, or rating of circuit breakers / ELB is detailed in below parts.  

·

The information of dimensions of the space necessary for correct installation of the appliance  

    including the minimum permissible distances to adjacent structures is detailed in below parts.

·

This appliance is intended to be used by expert or trained users in shops, in light industry and  

    on farms, or for commercial use by lay persons.

·

Instructions on additional charging of refrigerants are detailed below. 

Summary of Contents for RAS-1.0PNNBDH1

Page 1: ... RAS 1 0PNNBDH1 RAS 1 5PNNBDH1 RAS 2 0PNNBDH1 RAS 3 0PNNBDH1 RAS 4 0PNNBDH1 OUTDOOR UNITS DC INVERTER SERIES HO2021388HA ...

Page 2: ... is designed for the following temperatures It should be operated within this range DC Inverter Unitary Series Mode Outdoor Operation Temperature Range Model Maximum Minimum Cooling Operation 1 0 4 0HP 9K 36K 118 48 5 15 Heating Operation 3 0HP 24K 75 24 13 25 1 0 1 5 2 0 4 0HP 9K 12K 18K 36K 75 24 4 20 Storage Condition Temperature 13 140 25 60 Humidity 30 80 The numbers in the model represent th...

Page 3: ...tance with no connection and don t connect multiple devices to the same AC power supply Otherwise it may result in bad contact poor insulation unallowable current which could finally result in fire or electric shock After all installations are completed check to make sure that no refrigerant leakage occurs It will generate harmful substances if the refrigerant gas leaks in the interior area and ha...

Page 4: ...onditions and these means must be incorporated in the fixed wiring in accordance with the wiring rules If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard The appliance shall be installed in accordance with national wiring regulations Servicing shall only be performed as recommended by the equipment manuf...

Page 5: ...hanger EEV Service valve Electrical Wiring Diagram Refrigerant Flow Diagram Outdoor Unit Indoor Unit Terminal Terminal Power Supply Power Connecting Cord 1 0 1 5 2 0 3 0 4 0HP 9K 12K 18K 24K 36K SI SI L L N N L2 L1 NOTE Since there may be differences in some models terminal blocks wiring connection should be done according to letters on the terminal block Please disregard numbers in this case ...

Page 6: ...required for the affected device Install the unit horizontally Please install it in an area not affected by snowfall or blowing snow In areas with heavy snow please install a canopy a pedestal and or some baffle boards Avoid the following places for installation where air conditioner trouble is liable to occur Where there is much machine oil Salty places such as seaside Where sulfide gas is genera...

Page 7: ... avoid disturbing neighbors and to protect the environment it is necessary to install a drainage elbow and a drain hose to drain out the condensate water Please do the drainage work before the indoor unit and outdoor unit are connected Otherwise it will be difficult to install drainage elbow after the machine becomes immovable Connect the drain hose field supplied nside diameter i 5 8 in 15mm as s...

Page 8: ...itional refrigerant charge L 24 6 0 161 oz ft For 2 0 4 0HP 18K 36K Additional refrigerant charge L 24 6 0 376 oz ft Refrigerant Piping Model Outer Diameter of Pipe in mm Gas Liquid 1 0 1 5HP 9K 12K ø3 8 ø9 52 ø1 4 ø6 35 2 0HP 18K ø1 2 ø12 7 ø1 4 ø6 35 3 0HP 24K ø ø15 88 5 8 ø ø9 52 3 8 4 0HP 36K ø ø19 05 3 4 ø ø9 52 3 8 Pipe Length L Height Difference H Indoor Unit Outdoor Unit 3 Piping thickness...

Page 9: ... Good o 90 Burr Copper pipe Spare reamer Pipe cutter Flare nut Copper pipe Flaring tool Clutch type Wing nut type Die Copper pipe Flare nut Copper pipe Die York Smooth all around Inside is shining without any scratches 4 Piping Connection 1 Confirm that the valve is closed 2 Connect the indoor unit and the outdoor unit with field supplied refrigerant piping Suspend the refrigerant piping at certai...

Page 10: ... cover Using piping tape apply taping starting from the entry of outdoor unit Fix the end of piping tape with adhesive tape When piping has to be arranged through above ceiling closet or area where temperature and humidity are high wind additional commercially sold insulation for prevention of condensation 5 Air Tight Test Clamp field supplied Insulation field supplied Refrigerant pipe field suppl...

Page 11: ...rotect the wires electrical parts etc from rats or other small animals If not protected rats may gnaw at unprotected parts and at the worst a fire will occur Avoid the wiring from touching the refrigerant pipes plate edges and electrical parts inside the unit If not do the wires will be damaged and at the worst a fire will occur Install an ELB Electric Leakage Break in the power source If ELB is n...

Page 12: ...nd the transmitting cable to the conduit holder using the lock nut 3 Connect the power supply cable and the transmitting cable to terminal 4 Fasten the power supply cable and the transmitting cable with the cable clamp 5 Be sure to seal the holes when applying the putty Place the cables side to side Do not overlap the cables 6 Put the wiring distribution cover back after completion of the work Loc...

Page 13: ...e any trouble please contact local technical service center of our company for further information CAUTION Installation instructions Trial Run 11 NOTE 1 Follow local codes and regulations when selecting field wires and all the above are the minimum wire size 2 Use copper supply wires 3 When the transmitting cable is longer than 49 ft 15m a larger wire size should be selected 4 Install main switch ...

Page 14: ......

Page 15: ......

Page 16: ...ithout notice in order that Hitachi Johnson Controls Air Conditioning Inc may bring the latest innovations to their customers 2021 Johnson Controls Air Conditioning Inc Hitachi 2021 03 Version A Printed in China Hitachi Johnson Controls Air Conditioning Inc ...

Reviews: