 1 This air conditioner uses R410A refrigerant.

.

 2 Since the max. working pressure is 550 psig (3.8MPa) [R22:450 psig (R22:3.1MPa)], some of 

.

     the piping and installation and service tools are special.
 3

.

This air conditioner uses power supply

:

 208/230V ~/60Hz.

                                         

 

Please read these SAFETY PRECAUTIONS carefully to ensure correct installation.

·

Be sure to use a dedicated power circuit, and do not put other loads on the power supply.

·

Be sure to read these SAFETY PRECAUTIONS carefully before installation.

·

Be sure to comply with SAFETY PRECAUTIONS of installation manual, because it contains

    important safety issues. Definitions for identifying hazard levels are provided below with their 
    respective safety symbols.
        WARNING: Hazards or unsafe practices which COULD result in severe personal injury or death.
         CAUTION: Hazards or unsafe practices which COULD result in minor personal injury or product 
                           or property damage.

·

Please carefully file indoor and outdoor unit  manual away for future reference.

·

We recommend that this air conditioner be installed properly by qualified installation technicians in 

    accordance with the installation instructions provided with the unit. 
    Incomplete installation could cause damage by fire, electric shock, drop or water leakage.

·

Wiring must be done by a qualified electrician.

·

Install the air conditioner on a solid base that can support the unit weight.

    An inadequate base or incomplete installation may cause injury in the event the unit falls off from 
    the base.

·

Use the specified type of wire for safe electrical connections.

    Firmly clamp the interconnecting wires so that their terminals receive no external  stress.
    Incomplete connection may cause fire.

·

For wiring, use a cable long enough to cover the entire distance with no connection, and don’t  

    connect multiple devices to the same AC power supply.
   Otherwise, it may result in bad contact, poor insulation, unallowable current, which could finally result
   in fire or electric shock.  

·

After all installations are completed,  check to make sure that no refrigerant leakage occurs.

    It will generate harmful substances if the refrigerant gas leaks in the interior area and has contact 
    with heater or stove flame.

·

Perform the installation securely by referring to the installation manual.

    Incomplete installation could cause a personal injury arising from fire, electric shock, unit falling or 
    water leakage.

·

In accordance with the installation instructions for electrical work, please be sure to use a dedicated 

    line.

·

If the power supply circuit capacity or electrical work is not in place, it may cause a fire or electric 

    shock.

·

Attach the electrical cover to the indoor unit and the service panel to the outdoor unit securely.

·

If the electrical covers on the indoor unit or the service panel of the outdoor unit are not attached 

    securely, it could result in a fire or an electric shock due to dust water, etc.   

·

Please be sure to cut off the main power supply before the installation of indoor electronic PCB or 

    wiring. Otherwise, it will cause electric shock.

·

The device should be in accordance with the state provisions for installation wiring.

·

Pay attention to protecting the outdoor unit installation location. Avoid people or other small animals

    damaging electrical components. Please keep the surrounding environment of the outdoor unit 
    clean and tidy.

·

When installing or relocating the unit, make sure that no substance other than the specified 

    refrigerant (R410A) enters the refrigerant circuit.
    Any presence of foreign substance such as air can cause abnormal pressure rise or an explosion.

WARNING

Safety Precautions

1

California Residents Only-
Cancer and Reproductive Harm
www. P65 Warnings.ca.gov

Summary of Contents for RAS-1.0PNNBDH1

Page 1: ... RAS 1 0PNNBDH1 RAS 1 5PNNBDH1 RAS 2 0PNNBDH1 RAS 3 0PNNBDH1 RAS 4 0PNNBDH1 OUTDOOR UNITS DC INVERTER SERIES HO2021388HA ...

Page 2: ... is designed for the following temperatures It should be operated within this range DC Inverter Unitary Series Mode Outdoor Operation Temperature Range Model Maximum Minimum Cooling Operation 1 0 4 0HP 9K 36K 118 48 5 15 Heating Operation 3 0HP 24K 75 24 13 25 1 0 1 5 2 0 4 0HP 9K 12K 18K 36K 75 24 4 20 Storage Condition Temperature 13 140 25 60 Humidity 30 80 The numbers in the model represent th...

Page 3: ...tance with no connection and don t connect multiple devices to the same AC power supply Otherwise it may result in bad contact poor insulation unallowable current which could finally result in fire or electric shock After all installations are completed check to make sure that no refrigerant leakage occurs It will generate harmful substances if the refrigerant gas leaks in the interior area and ha...

Page 4: ...onditions and these means must be incorporated in the fixed wiring in accordance with the wiring rules If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard The appliance shall be installed in accordance with national wiring regulations Servicing shall only be performed as recommended by the equipment manuf...

Page 5: ...hanger EEV Service valve Electrical Wiring Diagram Refrigerant Flow Diagram Outdoor Unit Indoor Unit Terminal Terminal Power Supply Power Connecting Cord 1 0 1 5 2 0 3 0 4 0HP 9K 12K 18K 24K 36K SI SI L L N N L2 L1 NOTE Since there may be differences in some models terminal blocks wiring connection should be done according to letters on the terminal block Please disregard numbers in this case ...

Page 6: ...required for the affected device Install the unit horizontally Please install it in an area not affected by snowfall or blowing snow In areas with heavy snow please install a canopy a pedestal and or some baffle boards Avoid the following places for installation where air conditioner trouble is liable to occur Where there is much machine oil Salty places such as seaside Where sulfide gas is genera...

Page 7: ... avoid disturbing neighbors and to protect the environment it is necessary to install a drainage elbow and a drain hose to drain out the condensate water Please do the drainage work before the indoor unit and outdoor unit are connected Otherwise it will be difficult to install drainage elbow after the machine becomes immovable Connect the drain hose field supplied nside diameter i 5 8 in 15mm as s...

Page 8: ...itional refrigerant charge L 24 6 0 161 oz ft For 2 0 4 0HP 18K 36K Additional refrigerant charge L 24 6 0 376 oz ft Refrigerant Piping Model Outer Diameter of Pipe in mm Gas Liquid 1 0 1 5HP 9K 12K ø3 8 ø9 52 ø1 4 ø6 35 2 0HP 18K ø1 2 ø12 7 ø1 4 ø6 35 3 0HP 24K ø ø15 88 5 8 ø ø9 52 3 8 4 0HP 36K ø ø19 05 3 4 ø ø9 52 3 8 Pipe Length L Height Difference H Indoor Unit Outdoor Unit 3 Piping thickness...

Page 9: ... Good o 90 Burr Copper pipe Spare reamer Pipe cutter Flare nut Copper pipe Flaring tool Clutch type Wing nut type Die Copper pipe Flare nut Copper pipe Die York Smooth all around Inside is shining without any scratches 4 Piping Connection 1 Confirm that the valve is closed 2 Connect the indoor unit and the outdoor unit with field supplied refrigerant piping Suspend the refrigerant piping at certai...

Page 10: ... cover Using piping tape apply taping starting from the entry of outdoor unit Fix the end of piping tape with adhesive tape When piping has to be arranged through above ceiling closet or area where temperature and humidity are high wind additional commercially sold insulation for prevention of condensation 5 Air Tight Test Clamp field supplied Insulation field supplied Refrigerant pipe field suppl...

Page 11: ...rotect the wires electrical parts etc from rats or other small animals If not protected rats may gnaw at unprotected parts and at the worst a fire will occur Avoid the wiring from touching the refrigerant pipes plate edges and electrical parts inside the unit If not do the wires will be damaged and at the worst a fire will occur Install an ELB Electric Leakage Break in the power source If ELB is n...

Page 12: ...nd the transmitting cable to the conduit holder using the lock nut 3 Connect the power supply cable and the transmitting cable to terminal 4 Fasten the power supply cable and the transmitting cable with the cable clamp 5 Be sure to seal the holes when applying the putty Place the cables side to side Do not overlap the cables 6 Put the wiring distribution cover back after completion of the work Loc...

Page 13: ...e any trouble please contact local technical service center of our company for further information CAUTION Installation instructions Trial Run 11 NOTE 1 Follow local codes and regulations when selecting field wires and all the above are the minimum wire size 2 Use copper supply wires 3 When the transmitting cable is longer than 49 ft 15m a larger wire size should be selected 4 Install main switch ...

Page 14: ......

Page 15: ......

Page 16: ...ithout notice in order that Hitachi Johnson Controls Air Conditioning Inc may bring the latest innovations to their customers 2021 Johnson Controls Air Conditioning Inc Hitachi 2021 03 Version A Printed in China Hitachi Johnson Controls Air Conditioning Inc ...

Reviews: