(1) Operation temperature range
Item
Air Inlet Temperature of Outdoor Unit Air Inlet Temperature of Indoor Unit
(Non-room Temperature)
Cooling
-5
℃
DB
~
43
℃
DB
21
℃
DB/15
℃
WB
~
32
℃
DB/23
℃
WB
DB
:
Dry Bulb WB
:
Wet Bulb
(2) When transporting the outdoor unit, observe the following items. Please transport the unit to the installation location under
packed condition.
(3) When hanging the outdoor unit, please follow the description of the label attached to the outdoor unit.
After
removing the
package, in order to avoid body damage, the unit needs protecting by corrugated board or cloth if moving again.
●
When hanging outdoor unit, please do not tie the ropes on wooden base or the inside of hanging square holes.
Example
:
RAM-8MQ(D)
2. Transportation and Handling
木台
吊掛孔
錯誤
吊掛孔
繩索
繩索
正確
繩索位置
錯誤
繩索
CORRECT
INCORRECT
INCORRECT
Rope
Wooden Base
Rope
Rope
Square
Hole
Square
Hole
Corrugated Paper Frame
Do not remove corrugated
paper and plastic bands.
Do not apply any force to
this place.(Both Sides)
Rope
Wooden Base
Angle of ropes is more
than 60°.
Plywood or splint
thickness should
be more than 15mm.
Apply rope through the
square holes.
Corrugated Paper Frame
Do not apply any force to
this place.(Both Sides)
Do not remove corrugated
paper and plastic bands.
Angle of ropes is more
than 60°.
Rope
Plywood or splint
thickness should
be more than 15mm.
Apply rope through the
square holes.