– 4 –
1.
In quiet or stop operation, slight flowing noise of refrigerant in the refrigerating cycle is heard occasionally,
but this noise is not abnormal for the operation.
2.
When it thunders near by, it is recommended to stop the operation and to disconnect the power cord plug
from the power outlet for safety.
3.
In the event of power failure, the airconditioner will restart automatically in the previously selected mode
once the power is restored. In the event of power failure during TIMER operation, the timer will be reset
and the unit will begin or stop operating under a new timer setting.
4.
If the room air conditioner is stopped by adjusting thermostat, or missoperation, and re-start in a moment,
there is occasion that the cooling and heating operation does not start for 3 minutes, it is not abnormal
and this is the result of the operation of IC delay circuit. This IC delay circuit ensures that there is no
danger of blowing fuse or damaging parts even if operation is restarted accidentally.
5.
This room air conditioner should not be used at the cooling operation when the outside temperature is
below –10
°
C (14
°
F).
6.
This room air conditioner (the reverse cycle) should not be used when the outside temperature is below
–15
°
C (5
°
F).
If the reverse cycle is used under this condition, the outside heat exchanger is frosted and efficiency falls.
7.
When the outside heat exchanger is frosted, the frost is melted by operating the hot gas system, it is not
trouble that at this time fan stops and the vapour may rise from the outside heat exchanger.
CAUTION
Summary of Contents for RAC-70YH7
Page 35: ... 35 CIRCUIT DIAGRAM Remote Control ...
Page 36: ... 37 CIRCUIT DIAGRAM MODEL RAS 70YH7 ...
Page 37: ... 39 CIRCUIT DIAGRAM MODEL RAC 70YH7 ...
Page 39: ... 42 MODEL RAC 70YH7 P W B MAIN ...
Page 40: ... 43 P W B IPM BOARD P W B NF BOARD ...
Page 42: ... 45 51 53 53 55 57 49 29 66 23 25 25 25 25 ...
Page 46: ... 53 ...
Page 56: ... 66 220 240 220 240 3 15A RAC 70YH7 ...
Page 57: ... 67 AC220 240V DC260 360V ...
Page 58: ... 68 C001 C007 C015 C016 C026 C027 L004 L005 J25 J25 J25 J23 J58 J25 ...
Page 60: ... 70 ...
Page 61: ... 71 ...
Page 62: ... 72 3 15A Fuse ...
Page 63: ... 73 3 15A 3 15A DC260 360V ...
Page 66: ... 76 ...
Page 67: ... 77 ...
Page 68: ... 78 TROUBLE SHOOTING ...
Page 69: ... 79 DISCHARGE PROCEDURE AND METHOD TO STOP ENERGIZE THE POWER CIRCUIT ...
Page 70: ... 80 ...
Page 75: ... 85 2 Outdoor unit does not operate but receives remote infrared signal ...
Page 80: ... 90 AC220 240V AC240V P W Bs P W Bs Replace outdoor P W B Main P W Bs ...
Page 81: ... 91 Replace outdoor P W B Main Replace fan motor Replace outdoor P W B Main ...
Page 83: ... 93 ...
Page 84: ... 94 ...
Page 86: ... 96 CHECKING THE REMOTE CONTROLLER ...
Page 92: ...PM NO 0465E Printed in Malaysia RAS 70YH7 RAC 70YH7 ...