– 49 –
Reversing valve (heating on mode)
NOTE (9)
NOTE (5)
Dash period
Silent
1
Notes:
(1) Condition for entering into Cool Dashed mode. When fan set to “Hi” or “Auto mode” and temperature difference between indoor temperature and set temperature has a
corresponding compressor rpm (calculated value in Table 2) larger than CMAX.
(2) Cool Dashed will release when i) a maximum 25 minutes is lapsed and ii) room temperature is lower than set temperature –3
°
C (thermo off) and iii) when room temperature
has achieved setting temperature –1
°
C then maximum Cool Dashed time will be revised to 20 minutes. And iv) indoor fan is set to Lo and Med fan mode and v) change operation
mode.
(3) During Cool Dashed operation, thermo off temperature is set temperature (with shift value) –3
°
C. After thermo off, operation continue in Fuzzy control mode.
(4) Compressor minimum “ON” time and “OFF” time is 3 minutes.
(5) During normal cooling mode, compressor maximum rpm CMAX will maintain for 60 minutes if indoor temperature is lower than CLMXTP. No time constrain if indoor temperature
is higher than CLMXTP.
(6) When fan is set to “Hi”, compressor rpm will be limited to CKYMAX.
(7) When fan is set to “Med”, compressor rpm will be limited to CJKMAX.
(8) When fan is set to “Lo”, compressor rpm will be limited to CBEMAX.
(9) During Cool Dashed, when room temperature reaches set temperature –1
°
C compressor rpm is actual rpm x DWNRATEC.
Temperature
Calculated
difference
compressor rpm
1.66
2265 min
–1
2
2435 min
–1
2.33
2600 min
–1
2.66
2765 min
–1
3
2935 min
–1
3.33
3100 min
–1
3.66
3265 min
–1
4
3435 min
–1
4.33
3600 min
–1
4.66
3765 min
–1
5
3935 min
–1
5.33
4100 min
–1
5.66
4265 min
–1
6
4435 min
–1
6.33
4600 min
–1
6.66
4765 min
–1
7
4935 min
–1
7.33
5100 min
–1
7.66
5265 min
–1
8
5435 min
–1
8.33
5600 min
–1
8.66
5765 min
–1
9
5935 min
–1
9.33
6100 min
–1
9.66
6265 min
–1
10
6435 min
–1
10.33
6600 min
–1
10.66
6765 min
–1
11
6935 min
–1
Table 2
∆
TCMAX
Note:
1. See the data in Table 1 on
page 45 for each constant in
capital letters in the diagrams.
Summary of Contents for RAC-70YH7
Page 35: ... 35 CIRCUIT DIAGRAM Remote Control ...
Page 36: ... 37 CIRCUIT DIAGRAM MODEL RAS 70YH7 ...
Page 37: ... 39 CIRCUIT DIAGRAM MODEL RAC 70YH7 ...
Page 39: ... 42 MODEL RAC 70YH7 P W B MAIN ...
Page 40: ... 43 P W B IPM BOARD P W B NF BOARD ...
Page 42: ... 45 51 53 53 55 57 49 29 66 23 25 25 25 25 ...
Page 46: ... 53 ...
Page 56: ... 66 220 240 220 240 3 15A RAC 70YH7 ...
Page 57: ... 67 AC220 240V DC260 360V ...
Page 58: ... 68 C001 C007 C015 C016 C026 C027 L004 L005 J25 J25 J25 J23 J58 J25 ...
Page 60: ... 70 ...
Page 61: ... 71 ...
Page 62: ... 72 3 15A Fuse ...
Page 63: ... 73 3 15A 3 15A DC260 360V ...
Page 66: ... 76 ...
Page 67: ... 77 ...
Page 68: ... 78 TROUBLE SHOOTING ...
Page 69: ... 79 DISCHARGE PROCEDURE AND METHOD TO STOP ENERGIZE THE POWER CIRCUIT ...
Page 70: ... 80 ...
Page 75: ... 85 2 Outdoor unit does not operate but receives remote infrared signal ...
Page 80: ... 90 AC220 240V AC240V P W Bs P W Bs Replace outdoor P W B Main P W Bs ...
Page 81: ... 91 Replace outdoor P W B Main Replace fan motor Replace outdoor P W B Main ...
Page 83: ... 93 ...
Page 84: ... 94 ...
Page 86: ... 96 CHECKING THE REMOTE CONTROLLER ...
Page 92: ...PM NO 0465E Printed in Malaysia RAS 70YH7 RAC 70YH7 ...