– 94 –
LD301 b
links 9 time
.
Comm
unication error
.
Is DC 35V being output at
ter
minals C and D? (Nor
mally
,
DC 32.5-38.5V is output.)
Ye
s
Interf
ace rela
y
Coil ter
minal
Contact ter
minal
Is DC 35V being output across R713?
Is DC 12V being supplied across
the control side (coil ter
minal) of
interf
ace rela
y?
Is a v
oltage (at least 10V) being
gener
ated between the contact
ter
minals of interf
ace rela
y?
Chec
k the interf
ace curcuit.
Ye
s
Ye
s
No
No
Ye
s
D707 and C710 ma
y be def
ectiv
e
.
There is a def
ectiv
e section betw
een the
12V output of s
witching po
w
er supply on
the main P
.W
.B
. and interf
ace rela
y (also
,
chec
k f
or contact with solder
, etc.).
Repalce the interf
ace rela
y.
No