10. Temperature Detection Circuit
●
The outdoor units (this model) provides with the outdoor temperature thermistor, DEF (defrost) thermistor,
OH (overheat) thermistor and electric expansion valve thermistor so that they detect the temperatures of
the unit and control the system.
●
The circuit of the thermistors is shown as Fig. 10-1 for model RAS-70YHA1/RAS-80YHA1, and their roles
and temperature measuring points are shown as Table 10-1.
Fig. 10-1 Temperature Detection Circuit