![Hitachi RAC-50DH7 Service Manual Download Page 48](http://html.mh-extra.com/html/hitachi/rac-50dh7/rac-50dh7_service-manual_139700048.webp)
– 58 –
7. Drain pump trial run switch
●
This switch forcibly turns the drain pump on. When the drain pump trial run switch is turned on, the
timer indicator will blink seven times, and no remote signal will be accepted.
0V
5V
R533
Drain pump
trial run SW
(normally, Hi)
R534
Microcomputer
52
8. Float switch
●
This is a float type switch that monitors the drain level of drain pan. The switch will be activated and
will stop operation if the drain pump is faulty or drain hose is stopped up, disabling drainage, causing the
drain level to rise abnormally.
●
When the float switch is activated, the timer indicator will flash six times. Note that the float switch will
also be activated, disabling operation if the connector of float switch has defective contact or is
connected incompletely.
0V
0V
0V
5V
R621
C620
R539
Microcomputer
R620
CN16
FLOAT SW
Normally Hi (4.5V)
53
1
2
+
—
9. Drain pump drive circuit
58
5
12
1
12V
Drain pump motor
CN3
C116
IC711
Micro computer
Drain pump
C113
C115
C112
L102
NF1
L101
GRN1
C110
C108
C106
C105
VA03
3.15A FUSE
AC230V
C111
C109
C107
C114
DRAIN PUMP
- RELLAY
2
3
M
Drain pump drive circuit is using drain pump relay that control by micro computer pin no 58 to drive the drain
pump.
Summary of Contents for RAC-50DH7
Page 30: ... 29 CIRCUIT DIAGRAM Wired Remote Control ...
Page 31: ... 31 CIRCUIT DIAGRAM MODEL RAD 50DH7A RAD 60DH7A RAD 70DH7A ...
Page 32: ... 33 CIRCUIT DIAGRAM MODEL RAC 50DH7 RAC 60DH7 RAC 70DH7 ...
Page 35: ... 39 51 53 53 55 57 49 29 66 Heating ...
Page 76: ... 86 SELF DIAGNOSIS LIGHTING MODE MODEL RAC 50DH7 RAC 60DH7 RAC 70DH7 ...
Page 79: ... 89 2 Outdoor unit does not operate but receives remote infrared signal ...
Page 82: ... 92 CHECKING THE REMOTE CONTROLLER ...
Page 87: ... 97 16 ...