– 95 –
Is the indoor unit "timer lamp" blinking?
Yes
Yes
Yes
No
No
No
Trouble shoot according to the
self-diagnosis lighting mode.
Run the unit using the following remote controller settings:
In the cooling season, set the temperature to 16ßC in the cooling
mode.
In the heating season, set the temperature to 32ßC in the heating
mode.
Does the operation lamp light or blink?
Open the indoor unit and check the voltage
between pins Nos.1 and 3 of CN3 on the
indoor unit control P.W.B.
Normal: DC35V (32-38V)
Red
Brown
* When the unit is not in operation, the
voltage may drop to DC20V (18-23V).
(See 11-1 "Power Circuit" for details.)
Is the voltage correct?
Is the compressor running?
Check if the connecting cable
connected incorrectly? inserted
incompletely? or disconnected?
Not running
Running
Open the outdoor unit and observe the self-diagnosis
lamp (LD301). Count how many times the lamp blinks.
Blinks other than 1 time.
Blinks 1 time.
Can the unit be operated using the outdoor unit
service switch?
(See the nameplate on the outdoor unit for operating
instructions.)
Check the outdoor
electrical parts.
Check the indoor
electrical parts.
Check the refrigerating cycle.
In the event of overload limit cut or OH
thermistor temperature rise, use the
self-diagnosis memory function because
such failure may evade detection due to
ambient temperature variations or other
factors.
No
Yes
CHECKING THE INDOOR/OUTDOOR UNIT ELECTRICAL
PARTS AND REFRIGERATING
RAS_25_35_AW_087-108
2003.12.31, 10:59 AM
95
Summary of Contents for RAC-25YH4
Page 7: ... 5 RAS_25_35_AW_001 024 2003 12 31 10 43 AM 5 ...
Page 31: ... 29 RAS_25_35_AW_029 030_A3 2003 12 31 10 48 AM 29 ...
Page 32: ...RAS_25_35_AW_029 030_A3 2003 12 31 10 48 AM 30 ...
Page 34: ...RAS_25_35_AW_031 032 2003 12 31 10 49 AM 32 ...
Page 35: ... 33 RAS_25_35_AW_033 036_A2 2003 12 31 10 51 AM 33 ...
Page 36: ...RAS_25_35_AW_033 036_A2 2003 12 31 10 51 AM 34 ...
Page 37: ... 35 RAS_25_35_AW_033 036_A2 2003 12 31 10 51 AM 35 ...
Page 38: ...RAS_25_35_AW_033 036_A2 2003 12 31 10 51 AM 36 ...
Page 42: ...RAS_25_35_AW_037 040 2003 12 31 10 53 AM 40 ...
Page 44: ...RAS_25_35_AW_041 042_A3 2003 12 31 10 54 AM 42 ...
Page 45: ... 43 button RAS_25_35_AW_043 044_A3 2003 12 31 10 55 AM 43 ...
Page 46: ...RAS_25_35_AW_043 044_A3 2003 12 31 10 55 AM 44 ...
Page 48: ...RAS_25_35_AW_045 046 2003 12 31 10 55 AM 46 ...
Page 50: ...RAS_25_35_AW_047 054_A3 2003 12 31 10 57 AM 48 ...
Page 52: ...RAS_25_35_AW_047 054_A3 2003 12 31 10 57 AM 50 ...
Page 54: ...RAS_25_35_AW_047 054_A3 2003 12 31 10 57 AM 52 ...
Page 56: ...RAS_25_35_AW_047 054_A3 2003 12 31 10 57 AM 54 ...
Page 68: ... 66 RAS_25_35_AW_055 086 2003 12 31 10 59 AM 66 ...
Page 69: ... 67 Fig 3 4 RAS_25_35_AW_055 086 2003 12 31 10 59 AM 67 ...