– 9 –
NAMES AND FUNCTIONS OF EACH PART
INDOOR UNIT INDICATIONS
TIMER LAMP (Orange)
This lamp lights when the timer is working.
FILTER LAMP (Green)
When the device is operated for a total of about 200
hours, the FILTER lamp lights indicates that it is time
to clean the filter.The lamp goes out when the
“
(AUTO SWING)” button is pressed while the
operation is stopped.
OPERATION LAMP (Yellow)
This lamp lights during operation.
The OPERATION LAMP flashes in the following
cases during heating.
(1) During preheating
For about 2-3 minutes after starting up.
(2) During defrosting
Defrosting will be performed about once an hour
when frost forms on the heat exchanger of the
outdoor unit, for 5-10 minutes each time.
TEMPORARY SWITCH
●
Use this switch to start and stop when the remote controller does not work.
●
By pressing the temporary switch, the operation is done in automatic mode.
CAUTION
Turn off the circuit breaker or pull out
the power plug if the unit is not be
operated for a long period.
✩
If the power stays on and the unit is not operated, power is slightly consumed in the control circuit.
The power is saved by turning off the power switch (or the circuit breaker when the power is supplied
from the outdoor unit).
Attaching the air cleansing and deodorizing filters (Accessories) to the filter frame.
• Attach the air cleansing and deodorizing filters to the frame by
gently compress its both sides and release after insertion into
filter frame.
• The cooling capacity is slightly weakened and the cooling speed
becomes slower when the air cleansing and deodorizing filters
are used. So, set the fan speed to “HIGH” when using it in this
condition.
• Air cleansing and deodorizing filters are washable and reusable up to 20 times by using vacuum
cleaner or water rinse under running tap water. When you want to renew it, please ask your sales
agent.
Frame
POWER SWITCH
RAS_25_35_AW_001-024
2003.12.31, 10:43 AM
9
Summary of Contents for RAC-25YH4
Page 7: ... 5 RAS_25_35_AW_001 024 2003 12 31 10 43 AM 5 ...
Page 31: ... 29 RAS_25_35_AW_029 030_A3 2003 12 31 10 48 AM 29 ...
Page 32: ...RAS_25_35_AW_029 030_A3 2003 12 31 10 48 AM 30 ...
Page 34: ...RAS_25_35_AW_031 032 2003 12 31 10 49 AM 32 ...
Page 35: ... 33 RAS_25_35_AW_033 036_A2 2003 12 31 10 51 AM 33 ...
Page 36: ...RAS_25_35_AW_033 036_A2 2003 12 31 10 51 AM 34 ...
Page 37: ... 35 RAS_25_35_AW_033 036_A2 2003 12 31 10 51 AM 35 ...
Page 38: ...RAS_25_35_AW_033 036_A2 2003 12 31 10 51 AM 36 ...
Page 42: ...RAS_25_35_AW_037 040 2003 12 31 10 53 AM 40 ...
Page 44: ...RAS_25_35_AW_041 042_A3 2003 12 31 10 54 AM 42 ...
Page 45: ... 43 button RAS_25_35_AW_043 044_A3 2003 12 31 10 55 AM 43 ...
Page 46: ...RAS_25_35_AW_043 044_A3 2003 12 31 10 55 AM 44 ...
Page 48: ...RAS_25_35_AW_045 046 2003 12 31 10 55 AM 46 ...
Page 50: ...RAS_25_35_AW_047 054_A3 2003 12 31 10 57 AM 48 ...
Page 52: ...RAS_25_35_AW_047 054_A3 2003 12 31 10 57 AM 50 ...
Page 54: ...RAS_25_35_AW_047 054_A3 2003 12 31 10 57 AM 52 ...
Page 56: ...RAS_25_35_AW_047 054_A3 2003 12 31 10 57 AM 54 ...
Page 68: ... 66 RAS_25_35_AW_055 086 2003 12 31 10 59 AM 66 ...
Page 69: ... 67 Fig 3 4 RAS_25_35_AW_055 086 2003 12 31 10 59 AM 67 ...
Page 70: ... 68 RAS_25_35_AW_055 086 2003 12 31 10 59 AM 68 ...