The LD301 blinks 13 times.
EEPROM reading error
The LD301 blinks 9 times.
Communication error
Communication error
The LD301 blinks once.
Reset stopped
The LD301 blinks 9 times.
ǂ
Check the blinking frequency of the LD301.
No
Compressor stoppage
No
Correct the F cable connection.
Abnormal
Normal
Normal
Blinks 3times
Blinks 12 times
Blinking once
Other
No
Yes
Electrical parts abnormality
Check the F cable connection (for half insertion, connection by
using a thin cable, erroneous connection between terminal boards
, and , and other abnormalities).
Replace the outdoor electrical parts (in
the case of an abnormality in the
microcomputer or EEPROM).
Check that the indoor timer lamp blinks.
Check the indoor electrical parts.
(Check the temperature fuse in the
terminal board.)
(in the case of an abnormality in the
communication circuit).
Abnormality other
than compressor
stoppage
Run the product either by remote control or the
indoor forcible cooling switch.
Replace the outdoor electrical parts (in
the case of an abnormality in the
communication circuit).
Correct the abnormal location.
Abnormality in equipment other
than the electrical parts
The LD301 blinks once.
Reset stopped
If the indoor unit is either of the following states,
it will blink once.
·
Ionmist in progress
·
2 hours before the ON timer
Turn the power back on, run the
product either by remote control
or by using the forcible cooling
switch, and check the blinking
frequency of the LD301.
Replace the outdoor electrical parts
(in the case of an abnormality in the
reset circuit or microcomputer).
Conduct a check according to the
description of the LED blinking 9 times
given above.
Yes
Yes
No
No
Yes
Yes
If the LD301 is on, It is performing cooling or heating.
If the LD301 is on 2 second and off 0.3 second, the product is running with a heavy load. (This does not
constitute a failure.)
If the LD301 is bilnking each 0.25 second ,so please check the blinking number carefully of the lamp,and check it.
Identify the failure location.
LD301 blinking frequency each 0.25 second,
please check it carefully.
* This page is for RAC-25/35FXE
JW001 is open ?
or JW001 and JW002 is short ?
JW001 is open or JW001 and JW002 is short
Release back JW001 and JW002
1 2
3
Emplace the outdoor electrical parts
48
Summary of Contents for RAC-25FXE
Page 2: ... DANGER 2 ...
Page 6: ...SPECIFICATIONS 3 RAC 25 35FXE RAC 50FXE 1200g 6 ...
Page 13: ...WIRING DIAGRAM MODEL RAC 25 35F XE 13 ...
Page 14: ...WIRING DIAGRAM RAC 50FXE L E D O M 14 ...
Page 15: ...M基板BOM 中继端子台基板用部品 HIC基板BOM MODEL RAC 25 35F XE 15 ...
Page 16: ...MODEL RAC 50FXE 16 ...
Page 25: ...5 5 1 74 74 70 70 74 75 5 1 HIC P W B 10 11 12 74 70 75 25 ...
Page 27: ...2A Fuse DC300 330V 7 1 7 27 ...
Page 28: ...2A DC300 330V 60 100 28 ...
Page 29: ...L N 300 330 L N 50FXE 29 ...
Page 30: ...300 330 C021 C023 500 450V 16V R249 33 ACT IP CUT 30 30 ...
Page 34: ...5 5 1 74 74 70 70 74 75 5 1 HIC P W B 10 11 12 74 70 75 34 ...
Page 36: ...2A Fuse DC300 330V 7 1 7 36 ...
Page 37: ...2A DC300 330V 30 60 37 ...
Page 45: ...SELF DIAGNOSIS LIGHTING MODE MODEL RAC 25 35F X E 45 ...
Page 46: ...SELF DIAGNOSIS LIGHTING MODE MODEL RAC 50FXE 46 ...
Page 60: ...JCH WH RAC 50FXE RAC 2 5FXE RAC 3 5FXE NO 0128E 60 ...