During an automatic run, switching
the wind speed selector will not
change the wind speed.
Q1
Automatic operation
During heating, I turned off the
product by using the START/STOP
button. But the "operation lamp" is
blinking and the outdoor unit is
running.
Q1
Auto-fresh defrost
The product stops during heating
even though it is set to "30 ."
Q3
The product begins with a slight wind
during heating even though set to
"strong wind" or "weak wind."
Q2
The product sometimes fails to
produce a wind during heating.
Q1
Heating operation
The indoor unit produces a noise that
goes "shaaahhh" during
dehumidification.
Q1
Dehumidification
The compressor sometimes
stops during cooling.
Q1
Cooling operation
A1
Check if the heat
exchanger of the indoor
unit is covered with dew.
Wait for 3 to 4 minutes
until the dew disappears.
A1
That is a noise produced by refrigerant flowing through
the pipe.
A1
Defrosting is in progress. Wait 5 to 10 minutes until
the dew on the outdoor unit disappears.
At the first of the heating, the product will run for 30 seconds
with a slight wind. When set to strong wind, the product will
begin with a slight wind operation, producing a weak wind for
30 seconds, and then switch to strong wind.
A2
A3
When heating is conducted despite the high outdoor
temperature, the product may stop to protect its
equipment.
The "auto-fresh defrost" should be working. When
stopped, the product will check its outdoor unit for dew
and, if there is any dew, conduct defrosting and then
stop operating.
A1
A1
The product will switch automatically to automatic wind
speed. You cannot select strong or weak wind by
remote control but you can select wind and quiet.
Cooling when the room
temperature is low may
cause the heat exchanger
of the indoor unit to gather
dew.
SERVICE CALL Q&A
ć
Q2
A2
A
Q
Cold air comes out during a
dehumidifying operation.
The operation does not stop even by
setting the temperature higher than
room temperature on the remote
controller.
To improve the dehumidification efficiency performs
quiet fan operation. Therefore the air is cold and it is
not a malfunction.
It sets to perform dehumidifying operation by setting
the temperature slightly lower than remote controller
setting.
3
3
38
Summary of Contents for RAC-25FXE
Page 2: ... DANGER 2 ...
Page 6: ...SPECIFICATIONS 3 RAC 25 35FXE RAC 50FXE 1200g 6 ...
Page 13: ...WIRING DIAGRAM MODEL RAC 25 35F XE 13 ...
Page 14: ...WIRING DIAGRAM RAC 50FXE L E D O M 14 ...
Page 15: ...M基板BOM 中继端子台基板用部品 HIC基板BOM MODEL RAC 25 35F XE 15 ...
Page 16: ...MODEL RAC 50FXE 16 ...
Page 25: ...5 5 1 74 74 70 70 74 75 5 1 HIC P W B 10 11 12 74 70 75 25 ...
Page 27: ...2A Fuse DC300 330V 7 1 7 27 ...
Page 28: ...2A DC300 330V 60 100 28 ...
Page 29: ...L N 300 330 L N 50FXE 29 ...
Page 30: ...300 330 C021 C023 500 450V 16V R249 33 ACT IP CUT 30 30 ...
Page 34: ...5 5 1 74 74 70 70 74 75 5 1 HIC P W B 10 11 12 74 70 75 34 ...
Page 36: ...2A Fuse DC300 330V 7 1 7 36 ...
Page 37: ...2A DC300 330V 30 60 37 ...
Page 45: ...SELF DIAGNOSIS LIGHTING MODE MODEL RAC 25 35F X E 45 ...
Page 46: ...SELF DIAGNOSIS LIGHTING MODE MODEL RAC 50FXE 46 ...
Page 60: ...JCH WH RAC 50FXE RAC 2 5FXE RAC 3 5FXE NO 0128E 60 ...