– 77 –
LD301 blinks 12 times.
Fan lock error
.
Is CN24 connected?
Is the propeller fan
locked?
Have the 1A
fuse and
R107 blown?
Is +15V being generated?
Check voltage both between
CN18 4 and 5 on the main
P
.W
.B., and between
+15V
and
15-0V
(silk-screened) on
the power P
.W
.B.
If no output voltage is present
on the power P
.W
.B. side,
replace the power P
.W
.B.
Is the fan operating?
(An error occurs after the
fan operates for 2 minutes.)
Is the voltage between 4
and 6 at CN24 normal
?
(Normally
, the voltage is
above approx. DC1.7V
.)
Connect the connector
.
Remove any
obstructions.
Replace the fan motor
and main
P
.W
.B.
Is the voltage between 4 and
7 at CN24 normal
?
Check to see if the voltage is
within 2.5V
0.5V using a
tester
.
(In ef
fect, the output voltage
is alternately switched
between 5V and 0V
.)
Replace the main
P
.W
.B.
Replace the fan motor
.
Ye
s
No
No
No
Ye
s
No
No
No
No
No
Ye
s
Ye
s
Ye
s
Ye
s
Ye
s
Ye
s
07K394_RAS-14EH2_061-082_E
2007.10.31, 16:46
77
Summary of Contents for RAC-14EH2
Page 22: ...RAS 14EH2 CIRCUIT DIAGRAM 20 07K394_RAS 14EH2_020 021_A2_E 2007 10 31 17 19 20 ...
Page 25: ... 23 button 25 26 26 27 28 26 RAS 14EH2 07K394_RAS 14EH2_023_A3_E 2007 10 31 16 45 23 ...
Page 92: ... 90 07K394_RAS 14EH2_083 092_E 2007 11 12 09 12 90 ...
Page 94: ... 92 07K394_RAS 14EH2_083 092_E 2007 11 12 09 12 92 ...
Page 95: ...HITACHI AW NO 0029E RAS 14EH2 RAC 14EH2 07K394_RAS 14EH2_000cover_E 2007 10 31 17 14 3 ...