– 34 –
Voltage at point A
Waveform
T1 = Low speed
T2 = High speed
T2
T1
Voltage at point B
Waveform
T1
Voltage at point C
Waveform
Speed
(min
-1
)
T2
Voltage at point B (V)
(1400)
1
0
2
3
4
5
T1
T2
M
24
14
C751
0V
A
R751
C631
R631
0V
C
CN10
0V
5V
B
35V
Micro computer
Fan motor
Fig. 7-1
DC fan
motor output
DC fan motor
Speed
feedback
Fig. 7-2
Fig. 7-3
7. Fan Motor Drive Circuit
•
For the point A , 15.7 kHz PWM pulse will be output from
the pin
N
on the micro computer as shown in Fig. 7-2.
The pulse range will vary with different command speed.
•
The pulse is converted into the analog voltage by the
R751 and C751 and applied to the fan motor as the speed
command voltage.
Fig. 7-3 shows the relation between the voltage at the
point B and the speed. (Some differences will occur due
to the condition of the unit.)
•
The fan motor outputs the feedback pulse of the speed,
which is input into the pin
D
on the micro computer. This
pulse is equivalent to a frequency of 12/60 speed.
(Example: 1000 min-1 x 12/60 = 200 Hz)
The micro computer monitors the frequency and adjusts
the output pulse range of the pin
N
so as to keep the
command speed.
•
If the feedback pulse is 100 min-1 or less due to a locked fan motor or failure, the fan output will be
stopped temporarily as fan lock error. After 10 seconds, restart the output of the pulse. If fan lock
error is detected twice within 30 minutes, all units are stopped and the unit will come in the failure
mode. (The timer lamp will blink 10 times.)
Summary of Contents for RAC-14EH2
Page 22: ...RAS 14EH2 CIRCUIT DIAGRAM 20 07K394_RAS 14EH2_020 021_A2_E 2007 10 31 17 19 20 ...
Page 25: ... 23 button 25 26 26 27 28 26 RAS 14EH2 07K394_RAS 14EH2_023_A3_E 2007 10 31 16 45 23 ...
Page 92: ... 90 07K394_RAS 14EH2_083 092_E 2007 11 12 09 12 90 ...
Page 94: ... 92 07K394_RAS 14EH2_083 092_E 2007 11 12 09 12 92 ...
Page 95: ...HITACHI AW NO 0029E RAS 14EH2 RAC 14EH2 07K394_RAS 14EH2_000cover_E 2007 10 31 17 14 3 ...