ENGLISH
BAHASA MELAYU
THAILAND
–
25
–
HOW TO SET THE SLEEP TIMER
• By pressing the
(SLEEP) button, the desired sleep time
can be selected (1 hr., 2 hrs., 3 hrs. or 7 hrs. Monitoring).
• The Sleep (7 hrs. Monitoring) operation momentarily stops
cooling/dehumidifying after operating for three hours and then
the room’s temperature is monitored for the next 4 hrs..
While the room is monitored, the device automatically operates/
stops repeatedly (One Hour More Timer) according to the
conditions of the room.
1
• By pressing the
(SLEEP) button, the display changes as
follows.
• The device beeps when it has received the signal and the Sleep
operation starts. The specified Sleep Timer and the stop
operation time are displayed in the display of the remote
controller.
• The timer lamp of the indoor device turns on when configuring
the Sleep Timer.
• The fan speed during the Sleep operation is set at silent.
• The Sleep Timer settings of the fresh air in, exhaust and the air
purifier are 1, 2, 3 and 7 hrs.
• The “Off Timer”, used exclusively when sleeping, stops the fan after a specified time after
configuring the “Fan Speed” appropriate before going to bed, when cooling with the air
conditioning.
• The “Off Timer” stops the individual operation of the fresh air in, exhaust and air purifier after
a specified time.
1 hr.
Operation
➛
2 hr.
Operation
Sleep
(7 hrs. Monitoring)
3 hr.
Operation
➛
➛
➛
➛
Canceling the Sleep Timer
2
Sleep
timer
➝
Start
The device will be turned off by the
sleep timer and turned on by on-timer.
1
Set the ON-timer.
2
Press the
(SLEEP) button and set the sleep timer.
RAS13EX9G_EN(25-40).p65
3/8/07, 2:45 PM
25