– 4 –
SPECIFICATIONS
MODEL
FAN MOTOR
FAN MOTOR CAPACITOR
FAN MOTOR PROTECTOR
COMPRESSOR
COMPRESSOR MOTOR CAPACITOR
OVERLOAD PROTECTOR
OVERHEAT PROTECTOR
FUSE (for MICROPROCESSOR)
POWER RELAY
POWER SWITCH
TEMPORARY SWITCH
SERVICE SWITCH
TRANSFORMER
VARISTOR
FUSE CAPACITY (TIME DELAY FUSE)
THERMOSTAT
REMOTE CONTROL SWITCH
(LIQUID CRYSTAL)
RAS-08LH2/RAS-08LH2(B)
RAS-10LH2/RAS-10LH2(B)
RAS-14LH2/RAS-14LH2(B)
20 W
NO
NO
–
NO
NO
NO
3.15A
G4A
YES
YES
YES
NO
450NR
---------
YES(IC)
YES
---------
---------
30
W
2.5
μ
F, 450 VAC
3
μ
F, 450VAC
NO
20
μ
F, 450 VAC
YES
NO
NO
NO
NO
NO
NO
NO
NO
10 A
15 A
NO
NO
740g
min. 5m
max. 10m
min. 5m
max. 15m
ADDITIONAL
REFRIGERANT R410A
AT 5g PER EVERY
METER IF PIPE
LENGTH IS MORE
THAN 5m
ADDITIONAL
REFRIGERANT
R410A AT 20g
PER EVERY
METER IF
PIPE LENGTH
IS MORE
THAN 8m
UNIT
MAX. PIPES
REFRIGERANT CHARGING
VOLUME
(Refrigerant R410A)
RAC-08LH1
RAC-14LH1
RAC-10LH1
5RS080
UG4B124JX
45
μ
F, 450 VAC
700g
540g
5PS112
25
μ
F, 450 VAC
WITHOUT REFRIGERANT BECAUSE COUPLING IS FLARE TYPE
Summary of Contents for RAC-08LH1
Page 33: ... 31 MODEL RAC 08LH1 RAC 10LH1 RAC 14LH1 ...
Page 37: ... 35 WIRING DIAGRAM MODEL RAS 14LH2 14LH2 B RAC 14LH1 RAS 63CHA1 RAC 63CHA1 ...
Page 45: ... 49 MODEL RAS 14LH2 RAS 14LH2 B RAC 14LH1 ...
Page 53: ... 57 ...
Page 71: ... 75 PARTS LIST AND DIAGRAM OUTDOOR UNIT MODEL RAC 08LH1 ...
Page 73: ... 77 PARTS LIST AND DIAGRAM OUTDOOR UNIT MODEL RAC 10LH1 RAC 14LH1 ...