– 33 –
MODEL RAC-08LH1/10LH1/14LH1
COMPRESSOR MODEL
5RS080
5PS112
UG4B124JX
PHASE
SINGLE
RATED VOLTAGE
220 – 240 V
RATED FREQUENCY
50 Hz
LOCKED ROTOR CURRENT
12.4 A
20.3 A
27 A
POLE NUMBER
2
COMPRESSOR MOTOR
Compressor Motor Speci
fi
cations
CONNECTION
20°C
(68°F)
75°C
(167°F)
( )
RESISTANCE VALUE
!
CAUTION
When the Air Conditioner has been operated for a long time with the capillary tubes clogged or crushed
or with too little refrigerant, check the color of the refrigerant oil inside the compressor. If the color has
been changed conspicuously, replace the compressor.
RM = 5.193
RA = 5.557
EXTERNAL OVERLOAD RELAY
INTERNAL PROTECTOR
YES
NO
RM = 3.08
RA = 2.81
RM = 3.166
RA = 4.573
RM = 6.315
RA = 6.757
RM = 3.745
RA = 3.417
RM = 3.850
RA = 5.561