Section 6
6.2 On-screen Message Descriptions
z
6–7
6.2.1-3
Warning messages
No.
Message
Meaning of message
Remedy
1
Ink Low Warning
The ink level in the ink
tank is too low.
z
Add ink within
60 minutes.
2
Makeup Ink Low Warning
The makeup ink level in
the makeup ink tank is too
low.
z
Add makeup ink within
60 minutes.
3
Ink Shelf Life Exceeded
The cumulative ink
ejection time exceeded
the preselected alarm
time.
z
Replace the ink.
4
Operating Temperature
Too High
The ambient temperature
is higher than the upper-
limit operating
temperature.
z
Ensure that the ambi-
ent temperature is
within the operating
temperature limits.
5
Operating Temperature
Too Low
The ambient temperature
is lower than the lower-
limit operating
temperature.
z
Ensure that the ambi-
ent temperature is
within the operating
temperature limits.
6
Ink Heating Failure
Failure of the ink heating
section.
z
Contact your nearest
Hitachi distributor.
7
Battery Low
The voltage of the built-in
battery is too low.
z
Contact your nearest
Hitachi distributor.
z
When you start print-
ing, set the correct cal-
endar time again from
the date/time setup
screen.
(
Section 4.3, "Set-
ting the Date and
Time"
on page 4–7.)
8
Product Speed Matching
Error
The next speed-follow-up
signal is input while
printing is activated by the
previous follow-up signal.
z
Expand the interval
between the speed-fol-
low-up signals or
decrease the dividing
ratio.
9
Viscosity Reading
instability
Measurement results of
viscometer vary.
z
Contact your nearest
Hitachi distributor.
10
Viscosity Reading Out of
Range
Viscometer does not
function normally.
z
Contact your nearest
Hitachi distributor.
11 High Ink Concentration
Ink concentration is high.
z
Ink concentration is
now adjusted to nor-
mal level. If print qual-
ity is still poor, replace
ink with a new one.
12 Low Ink Concentration
Ink concentration is low.
z
Ink concentration is
now adjusted to nor-
mal level. If print qual-
ity is still poor, replace
ink with a new one.
Summary of Contents for PB Series
Page 10: ...x ...
Page 36: ...2 12 z 2 2 Shutdown Section 2 ...
Page 64: ...3 28 z 3 7 Recalling Saved Data Section 3 ...
Page 78: ...4 14 z 4 5 Controlling the Executable Functions Section 4 ...
Page 100: ...6 10 z 6 3 Viewing the Warning Condition and Fault Occurrences Section 6 ...
Page 102: ...7 2 z Emergency Procedures Section 7 ...
Page 108: ...8 6 z 8 3 Parts to be replaced periodically Section 8 ...