--- 13 ---
Body Ass'y [25]
Air escape
groove
O-ring (I.D10.7)
[50] (O-ring
mounted to the
outside of the
Valve Bushing
[49])
Part
NR 83AA3
NR 83AA2
Inside diameter 10.7 mm
Caution
Plunger (A) [48]
25 mm
26 mm
Inside diameter 11.5 mm
(3) Control valve section
Be careful not to make mistakes in mounting the following parts that were changed for the Model NR 83AA3
because these parts are similar to those of the Model NR 83AA2 but not interchangeable.
1
Never mount the O-ring (S-12)
for the Model NR 83AA2 to the
valve bushing of the Model
NR 83AA3 by mistake.
Otherwise, the O-ring may be
damaged when mounting the
valve bushing to the body ass'y,
and the damaged O-ring may
cause a malfunction when
selecting the single actuation
(single sequential actuation)
mechanism.
Do not mount the O-ring
(I.D 10.7) for the Model
NR 83AA3 to the valve bushing
of the Model NR 83AA2.
Otherwise, air leakage may
occur.
Do not mount plunger (A) for the
Model NR 83AA2 to the Model
NR 83AA3. Otherwise, plunger
(A) may contact the body ass'y
and it may be damaged when
raising the pushing lever ass'y to
the uppermost position.
There is no problem in mounting
plunger (A) for the Model
NR 83AA3 to the Model
NR 83AA2.
Do not mount the body ass'y for
the Model NR 83AA2 to the
Model NR 83AA3. Otherwise,
compressed air may be
remained in the valve in the
event the air hose is
disconnected with the trigger
pulled when selecting the single
actuation (single sequential
actuation) mechanism.
(The warning "Do not
disconnect air hose from nailer
with finger on trigger" is also
specified in the Instruction
Manual of the Model
NR 83AA3.) There is no
problem in mounting body ass'y
for the Model NR 83AA3 to the
Model NR 83AA2.
Summary of Contents for NR 83AA3
Page 45: ......