Item
Three-phase 200V class Specifications
Single-phase 200V class Specifications
WJ200 inverters, 200V models
002L
004L
007L
015L
022L
002S
004S
007S
015S
022S
Applicable motor size
Note1)
kW
0.2
0.4
0.75
1.5
2.2
0.2
0.4
0.75
1.5
2.2
HP
1/4
1/2
1
2
3
1/4
1/2
1
2
3
Rated capacity(kVA)
200V
0.4
0.9
1.3
2.4
3.4
0.4
0.9
1.3
2.4
3.4
240V
0.5
1.0
1.6
2.9
4.1
0.5
1.0
1.6
2.9
4.1
Rated input voltage
Three-phase: 200V-15% to 240V +10%, 50/60Hz
±
5%
Single-phase: 200V-15% to 240V +10%, 50/60Hz
±
5%
Rated output voltage
Note2)
3-phase: 200 to 240V (proportional to input voltage)
Rated output current (A)
1.4
2.6
4.0
7.1
10.0
1.4
2.6
4.0
7.1
10.0
Cooling method
Self-cooling
Force ventilation
Self-cooling
Force ventilation
Braking
(capacitive feedback)
Note3)
Approx.50%
Approx.20 to 40%
Approx.50%
Approx.20 to 40%
Weight
(kg)
0.7
0.8
0.9
1.2
1.3
0.7
0.8
0.9
1.2
1.3
(lb)
1.6
1.8
2.0
2.7
2.9
1.6
1.8
2.0
2.7
2.9
Common specification
項
目
仕
様
Protective housing
(JIS C 0920,IEC60529)
IP20
C
o
n
tr
o
l
Control method
Sinusoidal Pulse Width Modulation (PWM) control
Output frequency range Note4)
0.1 to 400 Hz
Frequency accuracy Note5)
Digital command:
±
0.01% of the maximum frequency
Analog command:
±
0.2% of the maximum frequency (25
°
C
±
10
°
C)
Frequency setting resolution
Digital input: 0.01 Hz
Analog input: Maximum output frequency/1000
Volt./Freq. characteristic
V/f control (constant torque, variable torque)
Overload capacity
150%/60 seconds
Acceleration/deceleration time
0.01 to 3,600.0 seconds (in linear or curved pattern)
、
2nd motors setting is possible
In
p
u
t s
ig
n
a
l
Freq. setting
External signal
:
adjustable resistor / 0 to +10 VDC /0 to 20 mA,
Modbus
、
Option operator
、
Dedicated operator
RUN/STOP
Order
External digital input signal(3-wire input possible), Modbus
Option Operator
、
Dedicated Operator
Intelligent input terminal
5terminals
Analog input
1terminal( O/OI terminal
:
Voltage input10bit/0 to 10V, Current input
:
10bit/0 to 20mA
selected with a
selection switch)
O
u
tp
u
t
s
ig
n
a
l
Intelligent output terminal
5 open-collector output terminals, 1 relay (1 from c-contact) output terminal
Pulse Output
1terminal
c
o
n
n
e
c
tio
n
RS-422
RJ45 Connector ,(Common with RS485
:
selecting it with a selection switch)Option Operator,ProDriveNext
RS-485
RJ45 Connector ,( Common with RS422
:
selecting it with a changeover switch)Modbus-RTU
G
e
n
e
ra
l
s
p
e
c
ific
a
tio
n
Temperature Note6)
Operating (ambient): -10 to 50
°
C, / Storage: -20 to 65
°
C
Humidity
20 to 90% humidity (non-condensing)
Vibration
5.9m/s
2
(0.6G), 10 to 55 Hz
Location
Altitude 1,000m or less, indoors (no corrosive gasses or dust)
Standards Compliance
UL
、
CE
、
c-UL
、
c-tick
Note1
)
The applicable motor refers to Hitachi standard 3-phase motor (4p). When using other motors, care must be taken to prevent the rated
motor current (50/60Hz) from exceeding the rated output current of the inverter.
Note2
)
The output voltage decreases as the main supply voltage decreases (except when using the AVR function). In any case, the output voltage
cannot exceed the input power supply voltage.
Note3
)
The braking torque via capacitive feedback is the average deceleration torque at the shortest deceleration (stopping from 50/60Hz as
indicated). It is not continuous regenerative braking torque. The average deceleration torque varies with motor loss. This value decreases
when operating beyond 50Hz.
Note4
)
To operate the motor beyond 50/60Hz, consult the motor manufacturer for the maximum allowable rotation speed.
Note5
)
To get motor stabilized operation, inverter output Frequency might exceeds preset maximum Freq.(A004/A204) by 2Hz in maximum.
Note6
)
Derating curve is shown on QRG (Refer to section 12.3 of QRG).