9-10
CONTROL AND FUNCTION
9.8
ADDITIONAL FUNCTION VIA DIP-SWITCH SETTINGS
A new DIP Switch is available on the PWBs of the indoor unit that provide additional functions via the settings on the switches.
ON
Air conditioner Indoor PWB
↕
OFF
Pin No.
Function
Switch Position / Setting
1
AUTO RESTART function
OFF
*
Enable
ON
Disable
2
DRY CONTACT function
OFF
*
Disable
ON
Enable
3
DRY CONTACT Logic Select
OFF
*
HI Input
Active
ON
LO Input
Active
4
HEATING / COOLING ONLY
MODE SELECT
OFF
*
NORMAL
(HEAT
AND
COOL)
OFF
HEATING
ONLY
ON
COOLING ONLY
5
OFF
*
ON
OFF
6
REMOCON ID SELECT
1
OFF
*
SELECT
ID A
ON
SELECT ID
B
NOTE:
“
*
“ Marking is position of shipping [FACTORY default setting]
9.8.1
AUTO RESTART FUNCTION
The AUTO RESTART function can be enabled or disabled by setting Pin No. 1 on the DIP SWITCH above to the ON or OFF
position accordingly.
9.8.2
HEATING/COOLING ONLY MODE SELECTION
When this function is enabled, the operation mode could be locked to either Heating Only (Heating or Fan) or Cooling Only
(Cooling, Fan or Dehumidifying) by setting the Pin No. 4 and 5 accordingly.
LOCKED MODE
REMARKS
HEATING ONLY
Unit will not enter into Cooling mode although cooling mode is selected using the remote controller.
COOLING ONLY
Unit will not enter into Heating mode although heating mode is selected using the remote controller.
DIP SW Label
Summary of Contents for MULTIZONE RAM-40NE2F
Page 11: ...DIMENSIONAL DATA 2 3 2 2 MULTIZONE OUTDOOR UNITS 2 2 1 2 ROOMS MULTIZONE RAM 40NE2F ...
Page 12: ...DIMENSIONAL DATA 2 4 2 2 2 2 ROOMS MULTIZONE RAM 53NE2F Unit mm ...
Page 13: ...DIMENSIONAL DATA 2 5 2 2 3 3 ROOMS MULTIZONE RAM 53NE3F Unit mm ...
Page 63: ...WIRING DIAGRAM 7 2 7 1 MULTIZONE 7 1 1 RAK 15QEF RAK 18REF RAK 25REF RAK 35REF RAK 50REF ...
Page 64: ...WIRING DIAGRAM 7 3 7 1 2 RAM 40NE2F RAM 53NE2F ...
Page 65: ...WIRING DIAGRAM 7 4 7 1 3 RAM 53NE3F ...
Page 68: ...REFRIGERANT CYCLE CYC8 3L 8 1 2 WALL TYPE RAK 50REF ...
Page 69: ...REFRIGERANT CYCLE 8 4 8 2 MULTIZONE OUTDOOR UNITS 8 2 1 2 ROOMS MULTIZONE RAM 40NE2F ...
Page 70: ...REFRIGERANT CYCLE CYC8 5L 8 2 3 2 ROOMS MULTIZONE RAM 53NE2F φ12 7 ...
Page 71: ...REFRIGERANT CYCLE 8 6 8 2 4 3 ROOMS MULTIZONE RAM 53NE3F ...
Page 74: ...CONTROL AND FUNCTION 9 3 9 2 SHIFT VALUE ...
Page 75: ...9 4 CONTROL AND FUNCTION 9 3 DISPLAY OPERATION MODE SETTING ...
Page 76: ...CONTROL AND FUNCTION 9 5 9 4 HOW TO CHANGE THE INTERMITTENT FAN CONTROL SETTING ...
Page 77: ...9 6 CONTROL AND FUNCTION 9 5 HOW TO CHANGE THE FAN SPEED IN COOLING MODE DURING THERMO OFF ...
Page 78: ...CONTROL AND FUNCTION 9 7 9 6 SETTING THE PREVENTION OF MUTUAL INTERFERENCE ...