225
5.
TGC clear timing
TCG can be cleared by the rising edge, falling edge, or both edges of the input capture input
signal.
Figure 9-13 shows the timing for clearing by both edges.
Figure 9-13 TCG Clear Timing
6.
Timer G operation modes
Timer G operation modes are shown in table 9-13.
Table 9-13
Timer G Operation Modes
Operation
Module
Mode
Reset Active
Sleep
Watch
Subactive Subsleep
Standby Standby
TCG
Input capture Reset Functions
*
Functions
*
Functions/ Functions/
Functions/ Halted
Halted
halted
*
halted
*
halted
*
Interval
Reset Functions
*
Functions
*
Functions/ Functions/
Functions/ Halted
Halted
halted
*
halted
*
halted
*
ICRGF
Reset Functions
*
Functions
*
Functions/ Functions/
Functions/ Held
Held
halted
*
halted
*
halted
*
ICRGR
Reset Functions
*
Functions
*
Functions
Functions/
Functions/ Held
Held
halted
*
halted
*
halted
*
TMG
Reset Functions
Held
Held
Functions
Held
Held
Held
Note:
*
When øw/4 is selected as the TCG internal clock in active mode or sleep mode, since the
system clock and internal clock are mutually asynchronous, synchronization is maintained
Input capture
input signal
Input capture
signal F
Input capture
signal R
TCG
N
N
H'00
H'00