24
2-4-6 Applica t ion for Condenser Load
Wh en closin g t he con denser cir cu it , t h e elect r ic ch a r ge Q = CE of t he con denser cor r espon din g t o t h e inst a nt an eou s
va lu e of power sour ce volta ge at closin g of cir cuit is pr om ptly supplied, a n d r ush cu rr ent flows.
Th e size of t h is r u sh cu r r en t is lim it ed by t h e lin e r esist a n ce a n d in du ct a n ce, a n d fu r t h er lim it ed by in ser t ion of
ser ies rea ctor (6 per cen t of con den ser ca pa cit y, k var )
Th e followin g t able gives th e condenser load a pplicat ions wh en r u sh cur r ent is less t h a n 10 t im es t h e r a ted cur r en t
of condenser by in ser t ion of ser ies r eact or .
Ta ble 19. Applica t ion to con den ser load
Applied capa cit y to
3-ph ase con denser cir cu it
k va r (A)
Applied capa cit y to
sin gle-ph a se con den ser cir cu it
k va r (A)
In ser tion of ser ies r ea ct or
2-pole ser ies
T
ype
200
~
220V
380
~
440V
220
~
240V
380
~
440V
H 10C, H 11,H S10
3(9)
4(6)
1.8(9)
2.4(6)
H 20,H S20
5(14)
8(12)
2.8(14)
4.8(12)
H 25,H S25
7(20)
12(17)
4(20)
6.8(17)
H 35,H S35
10(29)
18(26)
5.5(28)
10.5(26)
H 50H S50
13(38)
26(38)
7.5(38)
15(38)
H 65C
18(52)
35(51)
10(50)
20(50)
H 80C
22(64)
45(65)
12(60)
26(65)
H 100C
29(84)
55(79)
16(80)
31(78)
H 125C
34(98)
70(101)
19(95)
40(100)
H 150C
44(127)
88(127)
25(125)
50(125)
H 200C
53(153)
105(152)
30(150)
60(150)
H 250C
65(188)
130(188)
37(185)
75(188)
H 300C
80(231)
160(231)
46(230)
92(230)
H 400C
100(289)
200(289)
57(285)
115(288)
H 600C
150(433)
300(433)
86(430)
173(433)
Referen ce: Con ver sion of k va r a nd
μ
F
Sin gle-ph ase: [k va r ] = 2
π
×
10
-9
×
(F requ ency)
×
(
μ
F)
×
(Volt a ge)
2
3-ph ase: [k var ] =
√
3
×
2
π
×
10
-9
×
(F requ en cy)
×
(
μ
F )
×
(Volt a ge)
2
2-4-7 Applica t ion t o Open in g/Closin g of P rim ar y Side of Tra n sform er
Wh en a pplyin g volt a ge to t h e prim ar y side of t h e tr a nsfor m er , m a gn et ic sat u r a t ion ph en om en on occur s a t t h e ir on
cor e of t r a nsform er a n d a r ush cur r ent of excit a t ion flows. The a m ou n t of t h is r ush cur r en t va ries wit h t h e volt a ge
ph a se a n d loa d wh en closin g t h e con t a ct or ; t h e a m ou nt of r u sh cu r r en t will be a bou t 20 t im es t h e r a t ed cur r en t
of t h e t ra n sform er . Th e con t a ct or sh ou ld be select ed t h at is n ot welded by t h is r ush cu r ren t .
Summary of Contents for H100C
Page 2: ......
Page 9: ...5 Fig 1 H35 Horizontal Plunger type Fig 2 H300C Link structure ...
Page 36: ...32 Fig 28 ...
Page 54: ......