--- 12 ---
8-6. Insulation Tests
On completion of disassembly and repair, measure the insulation resistance, and conduct the dielectric strength
test.
Insulation resistance: 7 M
Ω
or more with DC 500 V Megohm Tester
Dielectric strength test: AC 4,000 V/1 minute, with no abnormalities ................... 220 V --- 240 V products
AC 2,500 V/1 minute, with no abnormalities ................... 110 V --- 127 V products
8-7. No-load Current Value
After no-load operation for 30 minutes, the no-load current value should be as follows.
Voltage (V)
Current (A) max.
110
3.4
120
3.1
230
1.7