background image

Ø230mm Angle grinder 2000W

MODEL NO.:

 sAg230

Thank you for purchasing a sealey product. manufactured to a high standard, this product will, if used according to these 

instructions, and properly maintained, give you years of trouble free performance.

IMPORTANT:

 PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE 

THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR 
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

1.  inTroducTion

1.1.    

elecTricAl  sAFeTY

 

‰

  

WArning!

 It is the user’s responsibility to check the following:

 

Check all electrical equipment and appliances to ensure that they are safe before using. Inspect power supply leads, plugs and    

 

all electrical connections for wear and damage. Sealey recommend that an RCD (Residual Current Device) is used with all electrical  

 

products. You may obtain an RCD by contacting your local Sealey stockist. 

 

If the product is used in the course of business duties, it must be maintained in a safe condition and routinely PAT (Portable  

 

 

Appliance Test) tested.

 

Electrical safety information, it is important that the following information is read and understood.

1.1.1.   

Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. 

1.1.2.   

Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.

1.1.3. 

  

imPorTAnT

: Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is fitted with the  

 

correct fuse - see fuse rating in these instructions.

 

8

   do  noT

 pull or carry the appliance by the power cable.

 

8

  

do noT

 pull the plug from the socket by the cable. Remove the plug from the socket by maintaining a firm grip on the plug.

 

8

   do  noT

 use worn or damaged cables, plugs or connectors. Ensure that any faulty item is repaired or replaced immediately by a   

  qualified electrician.

1.1.4. 

  

This product is fitted with a BS1363/A 13 Amp 3 pin plug. 

 

If the cable or plug is damaged during use, switch the electricity supply and remove from use. 

 

Replace a damaged plug with a BS1363/A 13 Amp 3 pin plug. If in doubt contact a qualified electrician.

 

Class II products are wired with live (brown) and neutral (blue) only are marked with Class II symbol.

 

A) Connect the BROWN live wire to the live terminal ‘L’.

 

B) Connect the BLUE neutral wire to the neutral terminal ‘N’.

 

C) After wiring, check that there are no bare wires and ensure that all wires have been correctly connected. 

 

Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight. 

 

8

   do  noT 

connect either wire to the earth terminal. 

 

Sealey recommend that repairs are carried out by a qualified electrician. 

1.2.    

generAl  sAFeTY

 

9

   Disconnect the grinder from the mains power before changing  accessories, servicing or performing any maintenance.

 

9

   Maintain grinder and discs in good condition. Check moving parts and alignment. If necessary use an authorised service agent.

 

9

   Replace or repair damaged parts. 

Use recommended parts only. Unauthorised parts may be dangerous and will invalidate the warranty.

 

‰

  

WArning! 

Always work with the grinder’s safety guard in place.

 

9

   Wear approved safety goggles, ear defenders, gloves and, if grinder generates dust, a dust mask. 

 

9

   Position the power cable clear of the grinding wheel to avoid cutting or snagging it. Hold grinder only by insulated gripping surfaces.

 

9

   Remove ill fitting clothing. Remove ties, watches, rings and other loose jewellery and contain long hair.

 

9

   Use grinder in a suitable work area. Keep area clean, tidy and free from unrelated materials and ensure adequate lighting.

 

9

   Maintain correct balance and footing,

 do noT

 over-reach. Ensure the floor is not slippery and wear non-slip shoes.

 

9

   Use only approved grinding discs and only use the normal grinding surface. 

 

9

   Check grinding disc to ensure there are no splits, cracks or other damage (see Section 6). If in doubt 

do noT 

use the disc.

 

9

   Grinding discs must be securely attached before use, but not over-tightened.

 

9

   Secure unstable workpiece with a clamp, vice or other adequate holding device and ensure the grinder is gripped with both hands.

 

9

   Keep non-essential persons away from the working area, use screens if necessary.

 

8

  

do noT

 operate the grinder if any parts are missing or the grinder is damaged.

 

8

  

do noT

 use the grinder for a task it is not designed to perform.

 

8

  

do noT 

operate the grinder where there are flammable solids, liquids or gasses.

 

‰

  

WArning! do noT 

grind any materials containing asbestos.

 

8

 

  do noT

 get the grinder wet or use in damp or wet locations. 

 

8

  

do noT

 switch the grinder on whilst the disc is in contact with the workpiece.

 

8

  

do noT

 cover the grinder air vents. To do so will overheat the machine.

 

8

  

do noT

 touch the workpiece immediately after grinding, it will be very hot.

 

8

  

do noT 

use the grinder as a fixed tool and 

do noT

 try to cool the grinding disc with water or other lubricants.

Original Language Version

© Jack Sealey Limited

Refer to 

instructions

Wear eye 

protection

 

Wear protective 

gloves

 

Wear ear 

protection

 

Wear safety 

footwear

 

Wear protective 

clothing

 

Wear a 

mask

 

Wear

respiratory 

mask (fumes)

Recommended fuse rating:

13Amp

S

AG230       Issue 1         13/09/19

Summary of Contents for SAG230

Page 1: ...been correctly connected Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight 8 8 DO NOT connect either wire to the earth terminal Sealey recommend that repairs are carried out by a qualified electrician 1 2 GENERAL SAFETY 9 9 Disconnect the grinder from the mains power before changing accessories servicing or performing any maintenance 9 9 Maintain...

Page 2: ...guard and spanner Fitted with over 2m of power cable and 3 pin plug Grinding disc not included order Model No PTC 230G 3 Specification Model SAG230 Motor Power 2000W Free speed 6500rpm Spindle size M14 x 2mm disc size Ø230mm Noise power 103dB A Noise pressure 92dB A Vibration Uncertainty 5 175m s2 K 1 5m s2 4 assembly WARNING Ensure that the grinder is unplugged from the power supply before assemb...

Page 3: ...der until you are sure that the power has been restored 5 3 Grinding HEAD ALIGNMENT 5 3 1 To rotate the grinding head to any orthogonal position 0O 90O 180O 270O depress the locking switch fig 1 and twist the head to the required position Ensure it is fully engaged in place before turning the power on 5 4 GRINDING 5 4 1 The key to effective operating is controlling the pressure and surface contact...

Page 4: ...The state of maintenance of the tool itself is also an important factor a poorly maintained tool will also increase the risk of Hand Arm Vibration Syndrome Health surveillance We recommend a program of health surveillance to detect early symptoms of vibration injury so that management procedures can be modified accordingly Personal protective equipment We are not aware of any personal protective e...

Reviews: