Drive chassis
Item
Component
Specification
Physical dimension
(W x D x H) (mm)
DBF
483 × 762 × 87 mm
DBS
482 × 565 × 88.2 mm
Weight/Mass (kg)
(Approximate)
DBF
19.3 kg
DBS
17 kg
Start-up time (min)
1
DBF
5 to 10 (min)
DBS
5 to 8 (min)
Required height
(EIA unit)
2
DBF
2U
DBS
Heat output (W)
DBF
120 W
DBS
116 W
Power consumption (VA)
DBF
130 VA
DBS
126 VA
Air flow (m
3
/min)
3
DBF
1.6 (m
3
/min)
DBS
2.2 (m
3
/min)
Notes:
1. The start-up time might be longer in proportion to the number of drive trays
connected. With a maximum configuration 1 controller chassis and 19 drive trays,
start-up time is approximately 8 minutes.
2. Can be mounted on the RKU rack. For the mounting, special rails for the rack and
decoration panels are required separately depending on the number of the
mounted storage systems.
3. The value is at maximum level.
VSP F700 mechanical specifications
Appendix B: System specifications
Hitachi Virtual Storage Platform F700 Hardware Reference Guide