3 - 16
ERROR MESSAGE
ERROR MESSAGE
ERROR MESSAGE
ERROR MESSAGE
ERROR MESSAGE
COUNTERMEASURE
COUNTERMEASURE
COUNTERMEASURE
COUNTERMEASURE
COUNTERMEASURE
TIME OUT ERROR ON FOCUS
Check the conditions of subject.
Make sure of the connection (PG1301) between lens and ANA
circuit board.
If this error message appears even when the adjustment is
performed 2 or 3 times, the autofocus circuit system is defective.
Replace the ANA circuit board.
TIME OUT ERROR ON ZOOM
Make sure of the connection (PG1301) between lens and ANA
circuit board.
If this error message appears even when the adjustment is
performed 2 or 3 times, the autofocus circuit system is defective.
Replace the ANA circuit board.
TIME OUT ERROR ON AF STEP
Check the conditions of subject.
If this error message appears even when the adjustment is
performed 2 or 3 times, the autofocus circuit system is defective.
Replace the ANA circuit board.
AF LIMIT OVER
Check the conditions of subject.
If this error message appears even when the adjustment is
performed 2 or 3 times, the autofocus circuit system is defective.
Replace the ANA circuit board.
AF ERROR
If this error message appears even when the adjustment is
performed 2 or 3 times, the autofocus circuit system is defective.
Replace the ANA circuit board.
TOO DARK
Insufficient lighting. Check the subject.
6.2
Error Message of Autofocus
ERROR MESSAGE
ERROR MESSAGE
ERROR MESSAGE
ERROR MESSAGE
ERROR MESSAGE
COUNTERMEASURE
COUNTERMEASURE
COUNTERMEASURE
COUNTERMEASURE
COUNTERMEASURE
THIS MODEL NEED NOT BE ADJUSTED
Adjustment is to be started for models that do not need adjustment.
PRESS ANY KEY.
Model selection is incorrect.
Initial setting for each model is incorrect.
Make sure of model selection and initial setting for each model.
(If they are incorrect, readjust all adjustment items.)
6.3
Error Message of Stabilizer
ERROR MESSAGE
ERROR MESSAGE
ERROR MESSAGE
ERROR MESSAGE
ERROR MESSAGE
COUNTERMEASURE
COUNTERMEASURE
COUNTERMEASURE
COUNTERMEASURE
COUNTERMEASURE
ERROR!
The temperature inside the video camera/recorder is too high:
ADJUSTMENT FAILED.
Turn power off, wait until the inside temperature drops sufficiently,
CAUTION!
and then perform readjustment.
Temperature of Camera is too high.
If this message still appears after adjustment has been performed
Please retry. [Shut down and wait a moment.]
several times, the CCD sensor is faulty.
PRESS ANY KEY
ERROR!
The temperature inside the video camera/recorder is too high:
ADJUSTMENT FAILED.
Turn power off, wait until the inside temperature drops sufficiently,
Please retry. Shut down and wait a moment.
and then perform readjustment.
If you failed again and again, CCD may failure.
If this message still appears after adjustment has been performed
PRESS ANY KEY
several times, the CCD sensor is faulty.
6.4
Error Message of Spot Noise
Summary of Contents for DZMV100E
Page 26: ...E1 21 ...
Page 27: ...E1 22 ...
Page 28: ...E1 23 ...
Page 29: ...E1 24 ...
Page 30: ...E1 25 ...
Page 31: ...E1 26 ...