--- 28 ---
9-6. Insulation Tests
On completion of reassembly after repair, measure the insulation resistance and conduct the dielectric strength
test.
Insulation resistance: 7 M
Ω
or more with DC 500 V Megohm Tester
Dielectric strength
: AC 4,000 V/1 minute, with no abnormalities
• • • • • • • •
220 V --- 240 V
(and 110 V for U.K. products)
AC 2,500 V/1 minute, with no abnormalities
• • • • • • • •
110 V --- 127 V
(except for U.K. products)
9-7. No-Load Current Value
After no-load operation for 30 minutes, the no-load current value should be as follows.
Voltage (V)
Current (A) Max.
6.2
5.9
5.7
5.4
3.1
3.0
2.8
240
230
220
127
120
115
110