Wiring diagram 8
Attaching the power unit block
Wiring when assembling the power supply block
Closeup arround FEB3
(1) Connect the circuit power supply and noice filter board with CNAC.
Connect the circuit power supply and the ballast power supply with CNDC.
(2) Pass the
TSW
, lamp fan lead, power supply fan lead and CNBA
T
through the incision of insulation seat.
(3) Put the FEB2 and FEB3, and make them to fix.
(4) Wiring of the CNBAR. Fix the insulation seat with tape.
(5) Style the
TSW cable to direction and fix it with the tape.
Wiring except for the power unit
(1)
Attach the igniter lead to bottom case with wire clamp #2200.
(2) Connect the CNRM to the remote board.
(3) Connect the CNSW to the switch board.
(4) Connect the CNBA
T
to the battery board.
Power unit case
V
iewpoint from arrow
The side of power
unit case B
Protection
sheet
Insert the CNBAR between case and sheet.
Fix the protection sheet with tape.
See the above diagram.
Style the CNBA
T
and power unit
fan cable being along the side of
power unit fan.
Wire the CNDC connector cable
near the center of C1
16 board.
Make sure to completely lock the hook when attaching
the CNAC. (It is impossible to check later
.)
Put the boss of FEB3 to the bottom case side.
T
urn it to the left.
Direction of
the FEB3 boss
remote board
fan
fan
boss
W
ork to prevent the cable slack.(T
o make it easy when assembling)
No cable stack between FEB2 and CN2.
Push the cable from FEB2 to FEB3 into the ditch to prevent the slack.
Make sure the FEB3 is not floating.
FEB3 interferce the engine when it is floating.
Put the excessive length of CNAC(from FEB3 to power unit case) to
the space between fan and boss.
If the engine was lifted when attaching it, FEB3 sometimes lifts the engine.
Push the FEB3 to the direction.
Switch board
ballast
ballast
heat sink
Power unit
(circuit)
POWER
fan
ZTP(L=75mm)
ZTP
Summary of Contents for CP-X807(EDX50WL)
Page 23: ...23 CP X807 EDX50WL Fig 3 Wireless Network Unit Configuration Fig 4 Execute ipconfig ...
Page 88: ...CP X807 EDX50WL 1 2 3 4 5 6 1 2 3 4 5 6 A B C D E F G POWER UNIT BALLAST 1 CONFIDENTIAL ...
Page 89: ...CP X807 EDX50WL 1 2 3 4 5 6 1 2 3 4 5 6 A B C D E F G POWER UNIT BALLAST 2 CONFIDENTIAL ...
Page 90: ...CP X807 EDX50WL 1 2 3 4 5 6 1 2 3 4 5 6 A B C D E F G POWER UNIT BALLAST 3 CONFIDENTIAL ...
Page 91: ...CP X807 EDX50WL 1 2 3 4 5 6 1 2 3 4 5 6 A B C D E F G POWER UNIT CIRCUIT 1 CONFIDENTIAL ...
Page 92: ...CP X807 EDX50WL 1 2 3 4 5 6 1 2 3 4 5 6 A B C D E F G POWER UNIT CIRCUIT 2 CONFIDENTIAL ...
Page 119: ...89 CP X807 EDX50WL MEMO ...
Page 120: ...QR73831 Printed in Japan JE CP X807 YK No 0598E ...