43
CP-X807(EDX50WL)
Wiring diagram 3
Wiring of the power supply block
Wiring of the power supply block
(1) Pass the CNPW1, CNPW2,
TSW and CNFG2 through the wiring clamp of power supply case.
Do not make excessive length of the cables. Make sure not to touch the primary
.
(2)
Attach the FEB1 to the CNPW1 and CNPW2.
(3)
Attach the FEB1 to the upper surface of power supply case with cable tie.
(4) Bundle the CNPW1, CNPW2,
TSW and CNFG2 with clamp.
(5)
Attach the CNFG2 to the power supply case with screw
.
(6) Pass the CNAC through the incision of insulation seat.
Area of Importance
Area of Importance
about 90
degrees
Incision of
Insulation seat
Wiring clamp
Power supply case
Attach the FEB1(ferrite core) to CNPW1 and CNPW2.
Make sure to completely lock the hook when attaching the FEB1.
Attach the FEB1 to the Network unit with cable tie (#2730).
Cut the excessive length of cable tie.
cable tie
Summary of Contents for CP-X807(EDX50WL)
Page 23: ...23 CP X807 EDX50WL Fig 3 Wireless Network Unit Configuration Fig 4 Execute ipconfig ...
Page 88: ...CP X807 EDX50WL 1 2 3 4 5 6 1 2 3 4 5 6 A B C D E F G POWER UNIT BALLAST 1 CONFIDENTIAL ...
Page 89: ...CP X807 EDX50WL 1 2 3 4 5 6 1 2 3 4 5 6 A B C D E F G POWER UNIT BALLAST 2 CONFIDENTIAL ...
Page 90: ...CP X807 EDX50WL 1 2 3 4 5 6 1 2 3 4 5 6 A B C D E F G POWER UNIT BALLAST 3 CONFIDENTIAL ...
Page 91: ...CP X807 EDX50WL 1 2 3 4 5 6 1 2 3 4 5 6 A B C D E F G POWER UNIT CIRCUIT 1 CONFIDENTIAL ...
Page 92: ...CP X807 EDX50WL 1 2 3 4 5 6 1 2 3 4 5 6 A B C D E F G POWER UNIT CIRCUIT 2 CONFIDENTIAL ...
Page 119: ...89 CP X807 EDX50WL MEMO ...
Page 120: ...QR73831 Printed in Japan JE CP X807 YK No 0598E ...