CP-X417W (C14-30AWL)
Each color part has same construction.By using swab and air duster, you can
easily remove dust from panel and optical filter.
3. Maintenance point
4. Cleaning the panels and optical filters
(1) Turn on the set and lit on the lamp.
(2) By using swab and air duster, remove the dust. Focusing dust makes you check the dust on screen.
• While removing the dust, separated dust will be blown
off by air cooling system.
• Please pay attention not to damage panels and optical
filters.
• Bend the top of SWAB a little if it is hard to insert the
SWAB.
Panel
Holder
Optical filter
5. Re-assembly
(1) Turn off the set and unplug the power cord.
(2) Remove an insulator from S801.
(3) Screw down the PWB assembly MAIN and connect the LCD panel flexible cables to the PWB assembly MAIN.
(4) Re-assemble the set.
(5) While re-assembling, please clean the intake filter by using a vacuum cleaner.
Actual formation
Summary of Contents for CP-X417W(C14-30AWL)
Page 13: ...13 CP X417W C14 30AWL 5 Troubleshooting Check points ...
Page 23: ...23 CP X417W C14 30AWL Fig 3 Wireless Network Unit Configuration Fig 4 Execute ipconfig ...
Page 54: ...54 CP X417W C14 30AWL ...
Page 81: ...CP X417W C14 30AWL 1 2 3 4 5 6 1 2 3 4 5 6 A B C D E F G POWER UNIT BALLAST 1 CONFIDENTIAL ...
Page 82: ...CP X417W C14 30AWL 1 2 3 4 5 6 1 2 3 4 5 6 A B C D E F G POWER UNIT BALLAST 2 CONFIDENTIAL ...
Page 83: ...CP X417W C14 30AWL 1 2 3 4 5 6 1 2 3 4 5 6 A B C D E F G POWER UNIT CIRCUIT CONFIDENTIAL ...
Page 108: ...QR73751 Printed in Japan JE CP X417W YK No 0597E ...