14
CP-X417W (C14-30AWL)
Power can not be turned on
Are
voltage
supplied at pins (8)
and (13) of E800 on the PWB
assembly MAIN in standby
mode?
Are voltage
supplied at pins (2),
(3), (5), (6) of E800 on the PWB
assembly MAIN in standby
mode?
NO
YES
(8): +6.0V
(13): GND
Does
LAMP (DK03) or
TEMP (DK02) indicator light
or blink?
YES
(2): +14V
(3): GND(for +14V)
(5): +17V
(6): GND(for +17V)
NO
*: Be sure to unplug the power cord before measuring resistance.
Measure resistance*
between pins (8) and (13) of
E800.
Disconnect TSW
from power unit circuit, and
measure resistance of
TSW.
Open
0
Ω
PWB assembly MAIN
Power unit (circuit)
Thermal switch (TSW)
Open
Power unit (circuit)
Fuse on the power unit
(circuit)
NO
Measure
resistance* between
pins (2) and (3), and between
pins (5) and (6) of
E800.
0
Ω
PWB assembly MAIN
Power unit (circuit)
Power unit (circuit)
Short
Open
Go to the next page
YES
Measure
resistance* between
pins (1) and (2) of S801 when
the lamp door is secure.
Lamp door
Re-attach lamp
door
Re-attach PWB
assembly MAIN
PWB assembly MAIN
Open
0
Ω
Summary of Contents for CP-X417W(C14-30AWL)
Page 13: ...13 CP X417W C14 30AWL 5 Troubleshooting Check points ...
Page 23: ...23 CP X417W C14 30AWL Fig 3 Wireless Network Unit Configuration Fig 4 Execute ipconfig ...
Page 54: ...54 CP X417W C14 30AWL ...
Page 81: ...CP X417W C14 30AWL 1 2 3 4 5 6 1 2 3 4 5 6 A B C D E F G POWER UNIT BALLAST 1 CONFIDENTIAL ...
Page 82: ...CP X417W C14 30AWL 1 2 3 4 5 6 1 2 3 4 5 6 A B C D E F G POWER UNIT BALLAST 2 CONFIDENTIAL ...
Page 83: ...CP X417W C14 30AWL 1 2 3 4 5 6 1 2 3 4 5 6 A B C D E F G POWER UNIT CIRCUIT CONFIDENTIAL ...
Page 108: ...QR73751 Printed in Japan JE CP X417W YK No 0597E ...