Note:
To prevent the storage system from being turned off by accident,
make sure the external power sources are not controlled by a wall switch.
Step 7: Cable the management console
A customer-supplied computer is used to set up and manage your storage system.
Before you begin
■
Obtain a Category 5 or better Ethernet cable.
■
Obtain a customer-supplied Windows-based PC that will serve as the management
console for setting up the storage system for the first time and, thereafter, to manage the
storage system. The management console must have a supported web browser: Internet
Explore version 11 or later, Chrome, or Firefox.
Procedure
1.
Connect one end of the Ethernet cable to the management port on the rear of either
controller.
2.
Connect the other end of the cable to a management console.
Step 8: Power on the storage system
After connecting the management console to the storage system, you can power on the
storage system.
Procedure
1.
Power on the PDUs.
2.
Confirm that the top (
POWER
) LED on the lower left front side of the controller is lit
amber, as shown in the following figure. If the storage system has a drive tray, confirm
that the
POWER
LED on the lower left front side of the drive tray is lit green.
Step 7: Cable the management console
Installing your storage system
Hitachi Virtual Storage Platform E990 Installation Guide
15