34
14.
Input / Output signal
1. Input signal
The level of the trigger signal input to HV-F203SCL is as follows.
(1) Input from CameraLink cable
LVDS level.
(2) Input from 12-pin connector
5Vp-p ± 0.5V
2. Output signal
The level of the VD/FLASH signal output from HV-F203SCL is as follows.
5Vp-p
15.
Spectral response
0.000
0.100
0.200
0.300
0.400
0.500
0.600
0.700
0.800
0.900
1.000
400
450
500
550
600
650
700
HV-F203SCL/GV Spectral sensitivity characteristics
R
el
at
iv
e
se
n
si
ti
vi
ty
r
es
po
n
se
Wave length [nm]
B
G
R
Summary of Contents for HV-F203SCL
Page 47: ...36 17 Dimensions...