15
(1) Transmission from master (normal process)
① Master sends data to slave.
② Slave acknowledges receipt of data by again returning ACK to master and end the handshake.
(2) Master reads data (normal process)
①
Master sends read command to slave.
②
Slave receives read command, then acknowledges by returning ACK code to master.
③
Slave sends read data to master.
④
M aster receives read data, then acknowledges by returning ACK code to slave.
Slave
(Camera)
Master (Machine)
1
2
Transmit data (STX-ETX.SUM)
ACK code (06H)
HITACH
3CCD
Master (Machine)
1
2
Read command (STX-ETX.SUM)
ACK code (06H)
4
3
Read data (ASCII code)
ACK code (06H)
Slave
(Camera)
HITACH
3CCD
Summary of Contents for HV-F203SCL