Hitachi Kokusai Electric HV-F203SCL Operation Manual Download Page 25

14 

10.

 

Remote control

 

 
1. Comms* specifications 
    ・Control system  

: Start-stop synchronization system 

    ・Transmission rate 

: 115200 bps 

    ・Data length 

 

: 8 bit 

    ・Star bit 

 

: 1 bit 

    ・Stop bit 

 

: 1 bit 

    ・Parity 

 

: None 

    ・Bit transfer 

 

: LSB first 

 

 

 

 

 

 

 

*Comms: Communications 

 
2. Comms control 

The remote control software controls all communications. Data send/receive (BSC handshake) is by transferring TEXT data 
to the camera controller chip. 

 
3. Comms procedure 
    The following pages indicate the camera controller chip and remote control software data protocol.  In the description, the 

camera is designated as slave and the software as master. 
・Receive protect timer (time out error) 
  The  receive  protect  timer  for  master  and  slave  processes  is  1  second.  For  example,  if  1  block  of  TEXT  data  is  being 

received, if the data interval exceeds 1 second, error is produced and the data are lost. An acknowledgment of data receipt 
is not produced. 

 
 
 

Summary of Contents for HV-F203SCL

Page 1: ...the use of Certain Hazardous Substances in Electrical and electronic Equipment Directive 2002 95 EC Thank you for purchase this fine Hitachi Kokusai Electric CCD camera Before using the camera please...

Page 2: ...product and to protect it from overheating and these openings must not be blocked or covered The openings should never be blocked by placing the product on a bed sofa rug or other similar surface Thi...

Page 3: ...perating instructions Adjust only those controls that are covered by the operating instructions as an improper adjustment of other controls may result in damage and will often require extensive work b...

Page 4: ...n der Ventilation Sie sind f r zuverl ssigen Betrieb des Ger tes und Schutz vor berhitzung erforderlich und d rfen nicht blockiert oder abgedeckt werden Die ffnungen sollten niemals dadurch blockiert...

Page 5: ...die Regelelemente verstellen die in den Bedienungsanleitungen behandelt werden da unangemessene Einstellung anderer Regelelemente Besch digung verursachen kann und oft betr chtliche Arbeit durch einen...

Page 6: ...ues pour la ventilation ainsi que pour garantir un fonctionnement en toute s curit de l appareil et le prot ger de toute surchauffe et ces ouvertures ne devront donc tre ni obstru es ni recouvertes Ne...

Page 7: ...ue les commandes couvertes par le mode d emploi en effet un r glage incorrect des autres commandes pourrait entrainer des dommages et n cessiteront souvent des travaux de r paration co teux par un tec...

Page 8: ...residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense WARNING Changes or modifications not expressly approved...

Page 9: ...ures for the Administration of the control of Pollution by Electronic Information Products known as China RoHS The table shows contained Hazardous Substances in this camera 2006 2 28 SJ T11364 2006 Pb...

Page 10: ...r an object of interest can cause ghosting of the object to appear in the picture The effect is more obtrusive with certain iris settings and lens types Select the scene layout and camera pointing dir...

Page 11: ...sts Excessively warm or cold environment Operating ambient temperature 10 to 50 Humid or dusty environment Place subjected to excessive vibration or shock Environment exposed to strong electric or mag...

Page 12: ...t making 10 9 12 PAINT BLACK Setting of paint black color level of R G and B can be separately varied 11 9 13 WHITE SHADING Setting of white shading correction 11 9 14 DNR Setting of noise reduction 1...

Page 13: ...2 13 1 Normal mode MODE OFF 30 13 2 Fixed shutter mode 32 13 3 ONE trigger mode 33 14 Input Output signal 34 15 Spectral response 34 16 Specifications 35 17 Dimensions 36...

Page 14: ...asking is the Hitachi innovation for optimizing color balance Saturation and hue of 6 colors Red Green Blue Cyan Magenta and Yellow can be adjusted independently to deliver the best color in image cap...

Page 15: ...stances are important If separation is too short color irregularity Is apt to occur at the top and bottom of the image Conversely if too long where the lens iris is a nearly fully open resolution is i...

Page 16: ...6 TYOUT 3 19 TYOUT 3 7 N U 20 N U 8 N U 21 N U 9 N U 22 N U 10 N U 23 N U 11 N U 24 N U 12 N U 25 N U 13 GND 26 N U INNER_SHIELD POW_IN SDR connector 3M or equivalent N U Not used The digital out cab...

Page 17: ...O SHN 10 12 RPCB or equivalent Plug matching cable plug HR10A 10P 12S 01 HIROSE or equivalent Note Please do not unplug and insert cable camera cable with a power supplied to a camera Install clamp fi...

Page 18: ...r operation and timing chart page 30 9 2 SHUTTER Setting of electronic shutter OFF Shutter operation set to OFF normal shutter 1 30 1 60 1 100 1 250 1 1000 1 2000 1 10000 1 50000 second Set to setting...

Page 19: ...ness of the output image will be practical level AGC MIN setting to lowest gain limit of an AGC 0 to 12 04dB AGC range for minimum gain limit Factory setting 0dB When become setting AGC MAX MIN it eff...

Page 20: ...LE GREEN n 256 LUTs for Green n is table number and that was chosen from the input level 0 to 255 The input level n is converted to the set value Factory setting is the same value to input video level...

Page 21: ...een saturation in 256 steps Factory setting is 128 Setting value toward 0 side makes pastel and 255 side makes colorful G HUE Adjust green hue 0 to 255 Green come near to cyan at 0 side and come near...

Page 22: ...ecessary correction data causes a phenomenon like branding When was executing by mistake please reexecute with a procedure and make it right correction data i Please build the taking picture environme...

Page 23: ...w sec The camera detects the pixel that level is higher than threshold and save it as white spot v After DETECT please check DETECTED value When some channels DETECTED value higher than 4000 then incr...

Page 24: ...is within 1200 The other is automatically adjusted so as not to exceed the 1200 in the setting 9 20 TEST PATTERN Setting of Video test pattern OFF Factory setting Test pattern OFF H RAMP Horizontal R...

Page 25: ...transferring TEXT data to the camera controller chip 3 Comms procedure The following pages indicate the camera controller chip and remote control software data protocol In the description the camera i...

Page 26: ...read command to slave Slave receives read command then acknowledges by returning ACK code to master Slave sends read data to master M aster receives read data then acknowledges by returning ACK code t...

Page 27: ...has occurred Master sends data but error detected framing over run error Master If the ACK response does not come within three seconds to re send the command Master send the correctly data Slave send...

Page 28: ...ment to the send data and repeats the sequence every 3 seconds for 3 times If unsuccessful after 3 attempts master aborts the sequence and ends communication Master Machine 1 2 3 Send data ASCII code...

Page 29: ...ata Slave fails to receive acknowledgment of read data and attempts to resend every 3 seconds for 3 times After the third failure slave aborts the sequence and ends communication Master Machine 1 2 6...

Page 30: ...and ETX 2 byte ASCII code d Text data format details transmission sequence Status Transmission data status 2 byte ASCII code Used for EEPROM write 0 write absent 1 write present ID No Camera peculiar...

Page 31: ...d data 0x81 Read command with some exceptions 1 Data 0x00 0x00 Common data 2 Upper Lower 0x00 3 Upper Mid Lower 5 Calculation method of checksum Example STX 1 2 3 4 5 6 7 ETX SUM STATUS ID NO AREA ADD...

Page 32: ...00 00 03 1E 1 50000 02 00 FF 01 08 08 00 00 03 1D VARIABLE 02 00 FF 01 08 FF 00 00 03 F9 VARIABLE VALUE 2Byte MIN 1 100000 s 02 00 FF 01 11 00 00 00 03 2B MAX 10 s 02 00 FF 01 11 06 00 00 03 25 AES MO...

Page 33: ...0 03 26 ON 02 00 FF 01 25 01 00 00 03 25 TABLE RED n MIN 0 02 00 FF 20 n 2 00 00 00 03 2 MAX 255 02 00 FF 20 n 2 FF 00 00 03 2 TABLE GREEN n MIN 0 02 00 FF 21 n 2 00 00 00 03 2 MAX 255 02 00 FF 21 n 2...

Page 34: ...03 22 MAX 255 02 00 FF 01 38 FF 00 00 03 F6 MAGENTA HUE MIN 0 02 00 FF 01 39 00 00 00 03 21 MAX 255 02 00 FF 01 39 FF 00 00 03 F5 BLUE SATURATION MIN 0 02 00 FF 01 3A 00 00 00 03 19 MAX 255 02 00 FF 0...

Page 35: ...00 00 03 16 START 2Byte MIN 02 00 FF 01 1F 00 00 00 03 16 MAX 02 00 FF 01 1F 03 5C 00 03 FB WIDTH 2Byte MIN 02 00 FF 01 20 00 64 00 03 21 MAX 02 00 FF 01 20 03 C0 00 03 15 TEST PATTERN OFF 02 00 FF 0...

Page 36: ...00 FF 81 44 00 00 00 03 1D LUT MODE 02 00 FF 81 25 00 00 00 03 1E TABLE RED n 02 00 FF 90 n 1 00 00 00 03 1 TABLE GREEN n 02 00 FF 91 n 1 00 00 00 03 1 TABLE BLUE n 02 00 FF 92 n 1 00 00 00 03 1 SHARP...

Page 37: ...00 00 03 1B PIXCEL CORRECTION MODE 02 00 FF 81 4B 00 00 00 03 0F RED THRESHOLD 02 00 FF 82 00 00 00 00 03 24 GREEN THRESHOLD 02 00 FF 82 01 00 00 00 03 23 BLUE THRESHOLD 02 00 FF 82 02 00 00 00 03 22...

Page 38: ...nfiguration please be sure to connect CameraLink cable to D OUT 1 If the cable is connected to D OUT 2 machine may break down Previous Cycle TCLK 13 889ns 72 0000MHz R7 1 R6 1 N U B7 B6 G7 G6 R7 R6 B3...

Page 39: ...L LVAL B5 B4 B3 B2 N U R9 1 B1 B0 B9 B8 N U N U R9 R1 1 R0 1 R8 R5 R4 R3 R2 R1 R0 X3 X2 X1 X0 CLKX Next Cycle TCLK 13 889ns 72 0000MHz Previous Cycle N U N U N U N U N U G7 G6 N U N U N U N U N U FVAL...

Page 40: ...B2 R10 1 R9 1 B1 B0 B9 B8 R11 R10 R9 R1 1 R0 1 R8 R5 R4 R3 R2 R1 R0 X3 X2 X1 X0 CLKX Next Cycle TCLK 13 889ns 72 0000MHz Previous Cycle N U N U N U N U N U G7 G6 N U N U G11 1 G10 1 N U FVAL LVAL N U...

Page 41: ...12 1 H 1200H 600H HEIGHT H HEIGHT 2 H 42 2H 26 2H 2 12 OFFSET 12 29 H 2 8 OFFSET 12 17 H 1 2 Shutter time The value of indicated in the above table for each condition Partial scan OFF Partial scan ON...

Page 42: ...function 2 Equation of total number of line for partial scan and binning mode The total number of line 22 OFFSET 12 HEIGHT 2 1202 HEIGHT OFFSET 12 is Ceiling function Frame rate 45000000 1920 The tot...

Page 43: ...1H 26 7 s Partial scan OFF Partial scan ON x is Ceiling function BinningVertical OFF BinningVertical ON BinningVertical OFF BinningVertical ON 1250H 625H 2 12 OFFSET 12 29 HEIGHT 1207 HEIGHT OFFSET 12...

Page 44: ...function BinningVertical OFF BinningVertical ON BinningVertical OFF BinningVertical ON 1250H 625H 2 12 OFFSET 12 29 HEIGHT 1207 HEIGHT OFFSET 12 1 H 2 8 OFFSET 12 38 HEIGHT 2 1202 HEIGHT OFFSET 12 1 H...

Page 45: ...2 Input from 12 pin connector 5Vp p 0 5V 2 Output signal The level of the VD FLASH signal output from HV F203SCL is as follows 5Vp p 15 Spectral response 0 000 0 100 0 200 0 300 0 400 0 500 0 600 0 70...

Page 46: ...second Auto 1 30 27 to 1 100000 second Variable 10 to 1 100000 second 15 Frame on demand Mode OFF Normal mode Fixed shutter mode ONE trigger mode Trigger input From CameraLink CC1 or DCIN SYNC 12pin...

Page 47: ...36 17 Dimensions...

Page 48: ...okusai Electric Europe GmbH Frankfurt Head Office SiemensStra e 9 D 63263 Neu Isenburg Germany Phone 49 0 6102 8332 0 Fax 49 0 6102 202616 London Office Windsor House Queensgate Britannia Road Waltham...

Reviews: