B.When Using Switch Box
MODE
TIMER
GRILL
VENTI
RESET
LOU
CHECK
FAN
ON
OFF
JIS box
(field-supplied)
3)
4)
ATTENTION
:
Always make sure to turn off the power of the indoor unit when performing electrical wiring
work. Performing electrical wiring work with the power on can damage the circuit boards of the indoor unit
Max. 16 indoor Units
Remote control Switch
REMOCON REMOCON
Terminal Board
Terminal Board
1P-0.75MM²
CAUTION
Refer to the Tecnical Catalog II provided with each indoor unit when performing electrical wiring work between the remote control switch and indoor
units for setting the refrigerant cycle number and the indoor unit address.
note
2)
3) Enter running model
MODE
CHECK
press this switch.
press this switch
RESET
A/C
UNIT
UNIT
UNIT
F A N
M4なべネジ
(
現地調達品
)
M4 Screws
(Field-Supplied)
Connect the terminals.
and the remote control switch.
Remove the
protection film.
Attach the remote control switch to the
holding bracket.Be careful not to pinch
the cable when attaching it.
Remove the protection film from the liquid
crystal display.
Electrical Box
of Indoor Unit
Electrical Box
of Indoor Unit
or more
M3.5 Screws
M3.5
Screws
M3.5
Screws
Twist Pair Cable with Shield Tube:
Use a 0.3 to 0.75mm cable for connecting.The maximum total cable length is up 30m.If the total cable length exceeds 30m, use a twist pair cable
with shield tube(1P-0.75mm or more).In that case,the maximum total cable length is up to 500m.If using in combination with the control timer,the
allowable total cable length is up to 100m.The use of a cable other than that specified above can cause of malfunction due to the effects of noise.
2
2
Keep a distance more than 30cm between the transmission line (remote control switch cable and transmission wires) and power source of the indoor
units. If not, the air-conditioner may not operate properly or malfunction may occur due to effect of power source noise.
In case of simultaneously controlling multiple indoor units, set the refrigerant cycle numbers and addresses of the indoor units without overlapping.
No gap shall exist between the remote control switch cable and hole of the remote cotrol switch case. If there is a gap, cover the gap with vinyl tape.
If not, malfunction may occur due to entrance of water droplets or insects.
3.
Electrical Wiring
4.
Checking Procedures
1)Turn ON the power supply for all the indoor units.
Although a portion of the LCD (liquid crystal display)
of the remote control switch may light immediately
after the
power is turned on, this is not a malfunction.
For the models with the auto-address function,
wait for 3 minutes apporoximately. The addreing is
automatically performed.(There is a case that 5 mi-
inutes is required according to the setting condition.)
Set the“TEST RUN”mode by pressing the
“MODE”and“CHECK”switch simultaneously
for more than 3 seconds
ATTENTION
When "00" is indicated, the auto-address function may be performing.
Cancel the "TEST RUN" mode and set it again.
A." " is displayed on the LCD.
Example when 4 indoor Units are
connected.
←
B.The total number of the indoor units connected is
indicated on the LCD.
C.In case that the indicated number is not correct, the auto-address function is not performed corr-
ectly due to incorrect wiring, the electric noise or etc.
Turn OFF the power supply and correct the wiring after checking the following points;
(Do not repeat turning ON and OFF within 10 seconds.)
1.
Power Supply for Indoor Unit is Not Turned ON or Incorrect Wiring.
2. Incorrect Connection of Connecting Cable between Indoor Units or
3.
Incorrect Setting of Rotary Switch and Dip Swiach
D. Check to ensure that the “TEST RUN” mode is not set.
Incorrect Connection of Controller Cable.
(The setting is overlapped.)on the Indoor Units PCB
4) Canceling “TEST RUN” Mode
1. When the unit is not operating,
2. When the unit is operating, press the RUN/STOP switch.
2. When the unit is operating,
RUN
STOP
HYXE-F01H
20
Summary of Contents for HYE-W01
Page 7: ......
Page 9: ......
Page 16: ...Model HYXE J01H Wired Remote Control Switch 7 ...
Page 22: ...Model HYDE E01H 7 Day Timer 13 ...
Page 24: ...Model HCCS H128H2C1YM HCCS H128H2C1NM Central Control 15 ...
Page 25: ...Model HCCS H247R4C1E Central Control 16 ...
Page 26: ...Model HYJ J01H Central Control 17 ...
Page 27: ...Central Control Model HYJM S01H 18 ...
Page 34: ...HYXE G01H 25 ...
Page 35: ...HYXE G01H 26 ...
Page 46: ...HYXE J01H 37 ...
Page 47: ...HYXE J01H 38 ...
Page 48: ...HYXE J01H 39 ...
Page 49: ...HYXE J01H 40 ...
Page 50: ...HYXE J01H 41 ...
Page 51: ...HYXE J01H 42 ...
Page 52: ...HYXE J01H 43 ...
Page 53: ...HYXE J01H 44 ...
Page 54: ...HYXE J01H 45 ...
Page 55: ...HYXE J01H 46 ...
Page 56: ...HYXE J01H 47 ...
Page 57: ...HYXE J01H 48 ...
Page 58: ...HYXE J01H 49 ...
Page 59: ...HYXE J01H 50 ...
Page 60: ...HYXE J01H 51 ...
Page 61: ...HYXE J01H 52 ...
Page 62: ...HYXE J01H 53 ...
Page 63: ...HYXE J01H 54 ...
Page 64: ...HYXE J01H 55 ...
Page 65: ...HYXE J01H 56 ...
Page 66: ...HYXE J01H 57 ...
Page 67: ...HYXE J01H 58 ...
Page 68: ...HYXE J01H 59 ...
Page 69: ...HYXE J01H 60 ...
Page 70: ...HYXE J01H 61 ...
Page 71: ...HYXE J01H 62 ...
Page 72: ...HYXE J01H 63 ...
Page 73: ...HYXE J01H 64 ...
Page 74: ...HYXE J01H 65 ...
Page 75: ...HYXE J01H 66 ...
Page 76: ...HYXE J01H 67 ...
Page 115: ...HYDEͲE01H Hisense HYDE E01H 106 ...
Page 116: ...HYDE E01H 107 ...
Page 117: ...HYDE E01H 108 ...
Page 119: ...HYXE A01H HYJE D02H HYXE A01H HYXE A01H HYXE A01H HYJE D02H HYJE D02H HYJE D02H HYDE E01H 110 ...
Page 120: ...HYXE A01H HYJE D02H HYDE E01H 111 ...
Page 121: ...HYDE E01H 112 ...
Page 122: ...HYDE E01H 113 ...
Page 123: ...HYDE E01H 114 ...
Page 124: ...HYXE A01H HYJE D02H HYDE E01H 115 ...
Page 125: ...HYXE A01H HYJE D02H HYDE E01H 116 ...
Page 126: ...HYJE D02H HYDE E01H 117 ...
Page 127: ...HYDE E01H 118 ...
Page 128: ...HYJE D02H HYXE A01H HYDE E01H 119 ...
Page 129: ...HYJE D02H HYJE D02H HYXE A01H Hisense Hisense HYDE E01H 120 ...
Page 173: ...HYJ J01H 164 ...
Page 174: ...HYJ J01H 165 ...
Page 175: ...HYJ J01H 166 ...
Page 176: ...HYJ J01H 167 ...
Page 177: ...HYJ J01H 168 ...
Page 178: ...HYJ J01H 169 ...
Page 179: ... R QRW KDV WKLV IXQFWLRQ DV HW HYJ J01H 170 ...
Page 180: ...HYJ J01H 171 ...
Page 181: ...HYJ J01H 172 ...
Page 182: ...HYJ J01H 173 ...