1. GENERAL
1.4 Unit installation
With the DC inverter technology, one outdoor unit can be connected with 5 indoor units at
most. The combination rate range is from 80% to 130%.
Model
(Btu/h)
Max. Combined Quantity of Indoor Units
12K/
14K
/18K
2
21K
/24K
3
27K
/36K
4
1.5 Working range
Power Supply
Working Voltage
176V ~ 253V
Voltage Imbalance
Within a 3% deviation from each voltage at the main terminal of outdoor unit
Starting Voltage
Higher than 85% of the Rated Voltage
Operating temperature range
This air conditioner is designed for the following outdoor operating temperatures.
Type
Mode
Outdoor operating temperature (
℃
)
maximum
minimum
Multi-Split Air Conditioner
(Heat pump type)
Cooling Operation
48
-15
Heating Operation
24
-15
Storage condition:
Temperature -25~60
℃
Humidity
30%~80%
42K
5
4