14.TROUBLESHOOTING
Fault
Code
Fault Description Possible Reason of Abnormality
How to Deal With
Remarks
23
24
25
26
27
28
29
30
45
62
Expansion valve A
tube (thin) sensor
fault
1. The wiring of the sensor for the
expansion valve A(thin tube)
connect loose;
2. The sensor for the expansion
A(thin tube) is failure;
3. The sampling circuit is
abnormally.
1. Reconnect the wiring of the
sensor for the expansion valve
A (thin tube);
2. Replace the sensor for the
expansion valve A (thin tube);
3. Replace the outdoor control
board.
Expansion valve B
(thin)tube sensor fault
1. The wiring of the sensor for
the expansion valve B (thin
tube) connect loose;
2. The sensor for the expansion
valve B(thin tube) is failure;
3. The sampling circuit is
abnormally
1. Reconnect the wiring of the
sensor for the expansion valve
B(thin tube);
2. Replace the sensor for the
expansion valve B(thin tube);
3. Replace the outdoor control
board.
Expansion valve C
(liquid) pipe sensor
fault
1. The wiring of the sensor for
the expansion valve C (liquid
pipe) is connected loosely;
2. The sensor of the expansion
valve C
(
liquid pipe
)
fails;
3. The sampling circuit fails.
1. Reconnect the wiring of the
sensor for the expansion valve
C (liquid pipe).
2. Replace the sensor for the
expansion valve C (liquid pipe);
3. Replace the outdoor control
board.
Expansion valve D
(liquid) pipe sensor
fault
1.The wiring of the sensor for the
expansion valve D (liquid pipe)
is connected loosely;
2.The sensor of the expansion
valve D (liquid pipe) fails;
3.The sampling circuit fails.
1. Reconnect the wiring of the
sensor for the expansion valve
D (liquid pipe);
2. Replace the sensor for the
expansion valve D (liquid pipe);
3. Replace the outdoor control
board.
Expansion valve A
(gas pipe)
sensor
fault
1. The wiring of the sensor for
the expansion valve A (gas
pipe) is connected loosely;
2. The sensor of the expansion
valve A (gas pipe) fails;
3. The sampling circuit fails.
1. Reconnect the wiring of the
sensor for the expansion valve
A (gas pipe);
2. Replace the sensor for the
expansion valve A (gas pipe);
3. Replace the outdoor control
board.
Expansion valve B
(
gas pipe
)
sensor
fault
1. The wiring of the sensor for
the expansion valve B (gas
pipe) connect is connected
loosely;
2. The sensor of the expansion
valve B (gas pipe) fails;
3. The sampling circuit fails.
1. Reconnect the wiring of the
sensor for the expansion valve
B (gas pipe);
2. Replace the sensor for the
expansion valve B (gas pipe);
3. Replace the outdoor control
board.
Expansion valve C
(gas pipe) sensor
fault
1. The wiring of the sensor for
the expansion valve B (gas
pipe) connect is connected
loosely;
2. The sensor of the expansion
valve C (gas pipe) is fails;
3. The sampling circuit fails.
1. Reconnect the wiring of the
sensor for the expansion valve
B (gas pipe);
2. Replace the sensor for the
expansion valve C (gas pipe);
3. Replace the outdoor control
board.
Expansion valve D
(gas pipe) sensor
fault
1. The wiring of the sensor for
the expansion valve B (gas
pipe) is connected loosely;
2. The sensor of the expansion
valve D (gas pipe) fails;
3. The sampling circuit fails.
1. Reconnect the wiring of the
sensor for the expansion valve
B (gas pipe);
2. Replace the sensor for the
expansion valve D (gas pipe);
3. Replace the outdoor control
board.
IPM fault
There are many reasons for this
failure. You can check the driver
board fault LED to
further
analyze the fault code of the
drive board and to learn about
what leads to the fault and how
to operate it. Specific information
can be seen in table 5, table 6.
See attached "analysis of the
driving board fault".
Summary of Contents for 2AMW-42U4RRA
Page 10: ...1 GENERAL Type Capacity Btu h View 1 to 5 indoor units 42K 6 ...
Page 15: ...3 OUTLINES AND DIMENSIONS 21K AMW3 24U4RFA Unit mm 11 ...
Page 16: ...3 OUTLINES AND DIMENSIONS AMW3 24U4RAA Unit mm 414 380 12 ...
Page 17: ...3 OUTLINES AND DIMENSIONS 27K Unit mm 414 380 13 ...
Page 18: ...3 3 O OU UT TL LI IN NE ES S A AN ND D D DI IM ME EN NS SI IO ON NS S Unit mm 42K 14 ...
Page 29: ...7 REFRIGERANT CYCLE 7 Refrigerant cycle 12K 14K 18K 21K 24K 25 ...
Page 32: ...8 WIRING DIAGRAM Electric wiring diagram 1982504 D 21K AMW3 24U4RFA 28 ...
Page 33: ...8 WIRING DIAGRAM AMW3 24U4RAA Electric wiring diagram 1957327 B 29 ...
Page 34: ...8 WIRING DIAGRAM 27K 36K 30 ...